6 Service Mode
6.1 Error Code Memory Function
1.
General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the latest. When the error is occurred
more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery, the battery is pulled out) The error
code is memorized to FLASH ROM when the unit has just before powered off.
2.
How to display
The error code can be displayed by ordering the following procedure:
Preparation:
1. Attach the Battery to the unit.
Note:
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
Step 1. The temporary cancellation of "INITIAL SETTINGS":
While keep pressing " UP of Cursor button" and MOTION PICTURE button simultaneously, turn the Power on.
Step 2. Execute the error code display mode:
Press the " LEFT of Cursor button", MENU/SET button and MOTION PICTURE button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display → Error code display → CAMERA INFO → Normal display → .....
3.
Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute Main item
Sub item
Error code
Contents (Upper)
Error Indication
High
4bits
Low 4
bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive
OIS
18*0
1000 PSD (X) error. Hall element (X axis) position detect error in OIS
unit.
OIS X
LENSu NG
OIS Unit
2000 PSD (Y) error. Hall element (Y axis) position detect error in OIS
unit.
OIS Y
OIS Unit
3000 GYRO (X) error. Gyro (IC7101) detect error on Main P.C.B.
GYRO X
GYRO NG
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
4000 GYRO (Y) error. Gyro (IC7101) detect error on Main P.C.B.
GYRO Y
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
5000 GYRO (R) error, Gyro (IC7101) detect error on Main P.C.B.
GYRO R
GYRO NG
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
6000 Drive voltage (X) error.
OISX REF
LENSu/LENS
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS ENGINE) AD value
Page 1 of 3
10/28/2017
file://\\royalfs\Service\Technical\Ms.dehghani\All SVC sent by CD\20\DMC-FT25EBAL...
Содержание DMC-FT25EB
Страница 15: ...Page 2 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 16: ...Page 3 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 24: ...Page 4 of 6 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 28: ...Page 2 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 44: ...Fig D12 Page 15 of 19 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 48: ...Fig D16 Page 19 of 19 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 52: ...Page 4 of 6 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...