![Panasonic DH-4MP1 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/panasonic/dh-4mp1/dh-4mp1_operating-instructions-manual_258119006.webp)
- 6 -
Power Control
ELB Test
DH -3 MP 1
Push On-Off
ELB Reset
Push Up
3. MAINTENANCE
(2) Shower Head cleaning.
1) Turn the Shower Plate anticlockwise and remove it from the Shower Head
with hand.
2) Clean the Shower Plate's holes by using a soft brush from time to time.
(Recommended once a week).
Soft Brush
Rubber Packing
Shower
Head
Shower Plate
Take care do not damage the holes of the Shower Plate during the cleaning.
The Rubber Packing shall be set on the Shower Head before fixing back the Shower Plate
to Shower Head. Do not remove other parts other than Shower Plate and Rubber Packing.
CAUTION
Correct Arrangement
Wrong Arrangement
Filter Unit
Straight Area
Straight Area
(3) Filter Unit Cleaning (Filter Unit is fixed to Filter Knob)
Clean the Filter of the Filter Unit with water once a week.
Clean the Filter Unit when hot water is not drawn normally.
Dismantle, cleaning and assemble of Filter Unit
Close the Main Water Valve.
Turn Water Volume Knob clockwise if it is blocking the Filter Knob.
Turn the Filter Knob anticlockwise and pull it out.
Filter Unit
O Ring
Clean the Filter Unit.
Please make sure the O Ring is not removed and shall be free from
foreign particle to avoid water leaking.
Insert the Filter Unit with correct arrangement
and tighten it properly (clockwise).
Turn the Water Volume Knob to its original position
base on Water Flow Rate Adjustment at page 5.
Main Volume Knob
Filter Knob
Water Volume Knob
CLEANING
FILTER
Switch “OFF” the Miniature Circuit Breaker (MCB)
before service.
(1) Main Body cleaning.
Be sure to switch “OFF” the Miniature Circuit Breaker beforehand.
1) Clean it with moist cloth.
2) Never use benzene, thinner, detergent, bleach, etc.
3) Do not spray water to the unit, not put wet towels on it.
4) Make sure to use suitable cloth to clean the Front Plate surface
to avoid scratch.