24
ENGLISH
Control by remote controller
Operation
Operation mode
Unified operation, individual
Unified stop, indivi-
Tempera-
Operation
Control
operation by central remote
dual stop by central
Stop
ture control
mode
mode
controller, or operation
remote controller, or
setting
controlled by timer
timer stop
Acceptance
0
Rejection
Rejection
10
ON/OFF control impossible
Rejection
Acceptance
by remote controller
(Example)
Acceptance
(Example)
1 (Example)
Rejection
Rejection
(Example)
(Example)
(Example)
Rejection
11
Acceptance
2
Rejection
Rejection
12
Only OFF control possible
Acceptance
by remote controller
Acceptance
Acceptance
3
Rejection
13
Operation by remote
controller (at time of
unified operation by
centralized control)
Stop by
remote
controller
Operation by remote
controller (at time of
unified operation by
centralized control)
The control
mode is “1”.
[Rejection] [Rejection] [Rejection] [Acceptance] [Acceptance]
▼
▼
▼
▼
▼
OPERATION MODE
The following five operation control modes can be selected along with the temperature setting and operation mode
by remote controller, for a total of twenty different modes. These twenty modes are set and displayed with control
modes of 0 to 19. (For further details, see EXAMPLE OF OPERATION SCHEDULE on the next page.)
●
ON/OFF control impossible by remote controller .......... Use this mode when operating and stopping from the
central remote controller only. (ON/OFF control by
the remote controller is disabled.)
●
Only OFF control possible by remote controller ............ Use this mode when executing the operation only by
the central remote controller, and executing only the
stop by remote controller.
●
Centralized ........................................................................ Use this mode when executing the operation only by
the central remote controller, and executing opera-
tion/stop freely by remote controller during the preset
hours.
●
Individual ........................................................................... Use this mode when executing operation/stop both
by central remote controller and remote controller.
●
Timer operation possible by remote controller ............... Use this mode when executing operation/stop by
remote controller during the preset hours, and not
starting operation by the central remote controller at
the programmed time of system start.
HOW TO SELECT THE CONTROL MODE
●
Select whether to accept or to reject the operation from the remote controller regarding the operation, stop,
temperature setting and operation mode setting, respectively, and determine the particular control mode from the
rightmost column of the table below.
Example
Temperature
control by
remote
controller
Operation
mode setting
by remote
controller