8.3. OXYGEN ENRICH OPERATION
8.3.1. Purpose
Increase usage range by enable oxygen enrichment only operation.
8.3.2. Oxygen Enrichment Control -1
A. Indoor fan control
1. Air flow volume manual
Air flow volume as set by remote control. Speed same as for Cool mode.
2. Air flow volum auto
Repetition of 8 pattern (a ~ h) as shown below.
Each pattern, 10s
XE9CK
XE12CK
Quiet
Program Air
No. B
820
870
No. A
790
840
No. C
760
810
W
C
30
30
However, if combined operation with other mode, priority is given to fan control of other mode.
Priority: Cool - Dry - Fan - Heat > Ionizer > Oxygen
B. Indoor air direction control
1. Air flow direction manual, auto
→
same as cooling operation.
However when combined operation with other mode, priority is given to air flow direction control of other mode.
Priority Heat - Cool - Dry - Fan > Ionizer > Oxygen
C. Start & Cancel condition of Oxygen enrich operation
1. By remote control ON/OFF button.
a. During Ionizer and Air Conditioner is OFF, if Oxygen button is pressed
→
Oxygen only operation.
b. During Ionizer only operation, if Oxygen button is pressed
→
I Oxygen enrich operation.
c. During Oxygen only operation, If Oxygen button is pressed
→
Oxygen operation stop.
d. During Oxygen only operation, if ON/OFF button is pressed
→
Mode (as remote control setting) ope Oxygen operation.
e. During Cool, Fan, Heat, Dry, Ionizer operation, if Oxygen button is pressed
→
Cool, Fan, Heat, Dry, I Oxygen operation, if Oxygen button is pressed.
f.
During Cool, Fan, Heat, Dry, I Oxygen operation, if Oxygen button is pressed.
→
Cool, Fan, Heat, Dry, Ionizer operation.
g. During Cool, Fan, Heat, Dry, I Oxygen operation, if ON/OFF button is pressed
→
All operation stop.
40
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Содержание CS-XE9CKE
Страница 10: ...4 Dimensions 10 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 11: ...11 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 12: ...5 Refrigeration Cycle Diagram 12 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 13: ...6 Block Diagram 13 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 14: ...7 Wiring Diagram 14 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 91: ...13 Technical Data 91 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 92: ...92 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 104: ...104 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 105: ...How to use electronic circuit diagram 105 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 106: ...18 1 REMOTE CONTROL 106 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 107: ...18 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD MAIN 107 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Страница 109: ...18 5 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARD MAIN 109 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...