27
Model
Indoor CS-RZ35WKEW
CS-RZ50WKEW
Outdoor CU-RZ35WKE
CU-RZ50WKE
Performance Test Condition
EUROVENT
EUROVENT
Power Supply
Phase, Hz
Single, 50
Single, 50
V 230
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW
0.85 3.50 3.90 0.98 5.00 5.40
BTU/h
2900 11900 13300 3340 17100 18400
kcal/h
730 3010 3350 840 4300 4640
Running
Current
A
– 4.40 – – 7.10 –
Input
Power
W
235 1.00k 1.19k 250 1.60k 1.80k
Annual
Consumption kWh
– 500 – – 800 –
EER
W/W
3.62 3.50 3.28 3.92 3.13 3.00
BTU/hW 12.34 11.90 11.18 13.36 10.69 10.22
kcal/hW 3.11 3.01 2.82 3.36 2.69 2.58
ErP
Pdesign kW
3.5
5.0
SEER (W/W)
6.2
6.9
Annual
Consumption
kWh 198
254
Class
A++
A++
Power
Factor
%
– 99 – – 98 –
Indoor Noise (H / L / QLo)
dB-A
42 / 30 / 20
44 / 37 / 33
Power Level dB
58 / – / –
60 / – / –
Outdoor Noise (H / L)
dB-A
48 / –
48 / –
Power Level dB
63 / –
63 / –
Heating
Capacity
kW
0.80 4.00 5.10 0.98 5.80 7.50
BTU/h
2730 13600 17400 3340 19800 25600
kcal/h
690 3440 4390 840 4990 6450
Running
Current
A
– 4.60 – – 7.60 –
Input
Power
W
195 1.05k 1.42k 210 1.70k 2.30k
COP
W/W
4.10 3.81 3.59 4.67 3.41 3.26
BTU/hW 14.00 12.95 12.25 15.90 11.65 11.13
kcal/hW 3.54 3.28 3.09 4.00 2.94 2.80
ErP
Pdesign kW
2.8
4.0
Tbivalent °C
-10
-10
SCOP (W/W)
4.6
4.4
Annual
Consumption
kWh 852
1273
Class
A++
A+
Power
Factor
%
– 99 – – 97 –
Indoor Noise (H / L / QLo)
dB-A
42 / 33 / 22
44 / 37 / 33
Power Level dB
58 / – / –
60 / – / –
Outdoor Noise (H / L)
dB-A
50 / –
49 / –
Power Level dB
65 / –
64 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP
3.70 / 1.26k / 2.94
5.43 / 2.04k / 2.66
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
3.30 / 1.35k / 2.44
4.62 / 2.00k / 2.31
Max Current (A) / Max Input Power (W)
6.3 / 1.42k
10.5 / 2.30k
Starting Current (A)
4.60