14
Model
Indoor CS-TZ20WKEW
CS-TZ25WKEW
Outdoor CU-TZ20WKE
CU-TZ25WKE
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 15 (49.2)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height different
m (ft)
15.0 (49.2)
15.0 (49.2)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
10 (0.1)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
16
16
Length mm
550
550
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row × Stage × FPI
2 × 14 × 17
2 × 15 × 21
Size (W × H × L)
mm
580 × 294 × 25.4
580 × 315 × 25.4
Outdoor
Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Corrugated Fin
Row × Stage × FPI
1 × 24 × 17
1 × 24:12 × 17
Size (W × H × L)
mm
18.2 × 504 × 710
36.4 × 504:252 × 713:684
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
Nil
Nil
Thermostat
Electronic Contol
Electronic Contol
Protection Device
Electronic Contol
Electronic Contol
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum
°C
32 23 32 23
Minimum
°C
16 11 16 11
Heating
Maximum
°C
30 – 30 –
Minimum
°C
16 – 16 –
Outdoor
Operation
Range
Cooling
Maximum
°C
43 26 43 26
Minimum
°C
-10 – -10 –
Heating
Maximum
°C
24 18 24 18
Minimum
°C
-15 -16 -15 -16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Standby power consumption
≤
2.0W (when switched OFF by remote control, except under self protection control).
6.
Specifications are subjected to change without prior notice for further improvement.