5 Features
1
Temperature
wave
2
Area search
3
Activity
detection
4
Absence
detection
5
Sunlight
detection
7m
131º
Rhythmic
temperature-
controlled pattern
to save energy
without sacrificing
comfort.
Human activity sensor detects presence/absence of
human beings and the movement speed of human
activities minimising the required amount of energy.
Adjusts power
to changes in
sunlight intensity.
■ Adjust the sunlight sensor sensitivity
Press
button for 5 seconds, press
to select sunlight sensitivity, then press
.
Press the
button or leave it untouched for 30 seconds to exit the setting.
The sensitivity level could be adjusted:
3
4
5
1
2
Level 3: Default sensitive level.
Level 1: Less sensitive to sunlight intensity.
Level 5: More sensitive to sunlight intensity.
Note
,
,
•
Can be selected at the same time and can be cancelled by pressing the respective button again.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89,6)
23 (73,4)
43 (109,4)
26 (78,8)
Min.
16 (60,8)
11 (51,8)
16 (60,8)
11 (51,8)
DBT : Dry bulb temperature, WBT : Wet bulb temperature