English
21
The following symptoms do not indicate malfunction.
Symptom
Cause
Mist emerges from indoor unit.
• Condensation effect due to cooling process.
Water flowing sound during operation.
• Refrigerant flow inside the unit.
The room has a peculiar odour.
• This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic
fan speed setting.
• This helps to remove the surrounding odour.
Operation is delayed a few minutes after
restarting.
• The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.
• Condensation or evaporation occurs on pipes.
TIMER indicator is always on.
• The timer setting repeats daily once set.
POWER indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the
operation when the ON timer has been set.
Cracking sound during operation.
• Changes of temperature caused the expansion/
contraction of the unit.
Discoloration of some plastic parts.
• Discoloration is subject to material types used in plastic
parts, accelerated when exposed to heat, sun light,
UV light, or environmental factor.
Louder noise at outdoor unit during early
operation of i AUTO-X.
• The compressor and fan rotate at higher speed to
boost cooling performance during initial operation.
Dust may have collected around the front
panel, grilles and wall surrounding the unit
after extended use.
• The dust accumulation is due to air purification effect of
negative ions from nanoe-G. Remove the dust regularly
with a clean dampened cloth.
Check the following before calling for servicing.
Symptom
Check
Operation in COOL mode is not working
efficiently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the filters.
• Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
• Insert the batteries correctly.
• Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the
remote control.
• Make sure the receiver is not obstructed.
• Certain fluorescent lights may interfere with signal
transmitter. Please consult authorised dealer.
Troubleshooting
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND
UNPLUG then please consult authorised
dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the
remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning
properly.
• Replace of safety devices should be
carried out by authorised dealer.
If the unit stops and the TIMER indicator blinks, use
the remote control to retrieve the error code.
ON
OFF
SET
TIMER
CANCEL
ON
OFF
SET
TIMER
CANCEL
Press for
5 seconds
Press for
5 seconds
to quit
checking
Press until you
hear beep sound,
then write down
the error code
Turn the unit off
and reveal the
error code to
authorised dealer
2
1
3
4
• For certain errors, you may restart the unit for limited
operation if there are 4 beeps when operation starts.
Cleaning instructions / T
roubleshooting
ACXF55-04370_YZ0517-1.indb 21
ACXF55-04370_YZ0517-1.indb 21
6/2/2017 2:30:37 PM
6/2/2017 2:30:37 PM