See "To learn more..." for details.

To optimise energy saving

To purify the air

nanoe-G

• nanoe-G starts automatically when the unit is 

turned on with 

OFF/ON

OFF/ON

 .

• Can be activated even when the unit is turned off. 

In this condition, the unit will operate as a fan with 

AUTO fan speed and flap swing.

To deactivate viruses/bacteria on the filter

nanoe-G

POWER

• After the unit is turned off, the nanoe-G in-filter 

deactivation may activate up to 150 minutes. 

Turning on the unit cancels this operation.

AIR SWING

To adjust airflow direction

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the flaps 

swings left/right and up/down automatically.

• In i AUTO-X mode, if AUTO is set, the horizontal 

flap is fixed at the lower position and shift to the 

upper position after reaches set temperature. The 

vertical flap movement depends on human activity 

sensor. If manual is set, the horizontal and vertical 

flap are fixed at the predetermined position.

• Do not adjust the flap by hand.

To set the timer

2 sets of ON and OFF timers are available 
to turn ON or OFF the unit at different preset 
times.

ON

OFF

SET

TIMER

CANCEL

CANCEL

1

2

3

1

Select ON or OFF 
timer

Example: 
OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

3

Confirm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 

to select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to 15 minutes) before the actual 

set time in order to achieve the desired 

temperature on time.

• Timer operation is based on the clock set in 

the remote control and repeats daily once set. 

For clock setting, please refer to Quick guide.

Note

QUIET

SLEEP

  

QUIET

  

• Can be activated in COOL and DRY mode and 

can be cancelled by pressing the respective 

button again.

• Cannot be selected at the same time.

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 

of time with previous operation mode and airflow 

direction. 

• This control is not applicable when TIMER is set.

How to use

ACXF55-04370_YZ0517-1.indb   17

ACXF55-04370_YZ0517-1.indb   17

6/2/2017   2:30:35 PM

6/2/2017   2:30:35 PM

Содержание CS-S9TKV

Страница 1: ...cciones de instalaci n incluidas antes de la instalaci n El control remoto viene embalado en la unidad interior y debe ser retirado por el instalador antes de la instalaci n Operating Instructions Air...

Страница 2: ...ga la refrigeraci n r pida al instante y la comodidad de la refrigeraci n que dura todo el d a Aplicable para la configuraci n AUTO de solapa horizontal ECONAVI INVERTER La perfecta tecnolog a de ahor...

Страница 3: ...o cerca de focos l mparas o de electrodom sticos que provoquen calor con el fin de evitar que el funcionamiento del sistema sea deficiente Las ilustraciones de este manual sirven nicamente para descri...

Страница 4: ...Una instalaci n y un manejo inadecuado provocar fugas una descarga el ctrica o un incendio Confirme con un distribuidor o especialista autorizado el uso de cualquier tipo de refrigerante especificado...

Страница 5: ...olvente o pulidor en polvo para evitar da os a la unidad o corrosi n en la unidad No use para la preservaci n de equipos de precisi n alimentos animales plantas trabajos art sticos u otros objetos Est...

Страница 6: ...el confort mientras duerme CANCEL Esta operaci n le proporciona un ambiente confortable mientras duerme Ajustar autom ticamente la temperatura del patr n del sue o durante el per odo de activaci n El...

Страница 7: ...o predeterminados ON OFF SET TIMER CANCEL CANCEL 1 2 3 1 Seleccione el temporizador de ENCENDIDO o APAGADO Ejemplo APAGADO a las 22 00 Cada vez que se presiona OFF Cancel 2 Ajuste la hora 3 Confirme S...

Страница 8: ...uz solar empezar n a detectar Funcionamiento del sensor de actividad humana ECONAVI Detecci n de presencia y actividad humana la unidad controla la temperatura del recinto para ahorrar energ a Modo Hu...

Страница 9: ...ermanezca inm vil durante cierto tiempo No coloque objetos grandes cerca del sensor y mantenga unidades de calefacci n o humidificadores alejados del rea de detecci n del sensor Puede dar lugar a un m...

Страница 10: ...o del panel delantero Generador nanoe G Una vez cada 2 semanas Limpie con un bastoncillo de algod n seco No toque durante el funcionamiento Filtro de aire Una vez cada 2 semanas Lave enjuague los filt...

Страница 11: ...toma Verifique El modo COOL FR O no funciona eficientemente Ajuste correctamente la temperatura Cierre todas las puertas y ventanas Limpie o reemplace los filtros Despeje cualquier obstrucci n en las...

Страница 12: ...satisfaction on a hot day and cooling comfort that goes on all day long Applicable for horizontal flap AUTO setting ECONAVI INVERTER The Perfect Energy Saving Technology ECONAVI detects where energy...

Страница 13: ...m the remote control receiver of the indoor unit The temperature control shall be located far from bulbs lamps and appliance that produce heat to prevent the incorrect operation The illustrations in t...

Страница 14: ...r specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not install the unit in a potentially explosive...

Страница 15: ...ater benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality de...

Страница 16: ...ort while sleeping CANCEL This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation period The indoor u...

Страница 17: ...OFF the unit at different preset times ON OFF SET TIMER CANCEL CANCEL 1 2 3 1 Select ON or OFF timer Example OFF at 22 00 Each time pressed OFF Cancel 2 Set the time 3 Confirm SET TIMER To cancel ON...

Страница 18: ...d the sunlight sensor will start to detect Human activity sensor operation ECONAVI Detecting human presence and activity the unit controls room temperature to save energy Mode Human Low activity Norma...

Страница 19: ...eriod of time Do not place large objects near the sensor and keep away heating units or humidifier from the sensor s detection area They may cause sensor malfunction i AUTO X i AUTO X After providing...

Страница 20: ...ds and center of the front panel nanoe G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to...

Страница 21: ...Check Operation in COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet ven...

Страница 22: ...Memo 22 ACXF55 04370_YZ0517 1 indb 22 ACXF55 04370_YZ0517 1 indb 22 6 2 2017 2 30 38 PM 6 2 2017 2 30 38 PM...

Страница 23: ...Memo 23 ACXF55 04370_YZ0517 1 indb 23 ACXF55 04370_YZ0517 1 indb 23 6 2 2017 2 30 38 PM 6 2 2017 2 30 38 PM...

Страница 24: ...de ser usado en combinaci n con un s mbolo qu mico En este caso el mismo cumple con los requerimientos establecidos por la Directiva para los qu micos involucrados English Information for Users on Col...

Отзывы: