Panasonic CS-RZ25WKRW Скачать руководство пользователя страница 4

4

 Safety precautions

To prevent personal injury, injury to others or property 
damage, please comply with the following: 
Incorrect operation due to failure to follow instructions 
below may cause harm or damage, the seriousness of 
which is classifi ed as below:
This appliances is not intended for accessibility by the 
general public.

WARNING

This sign warns of death 
or serious injury.

CAUTION

This sign warns of injury 
or damage to property.

The instructions to be followed are classifi ed by the 
following symbols:

This symbol denotes an action that 
is PROHIBITED.

These symbols denote actions 
COMPULSORY.

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they 
have been given supervision or instruction 
concerning use of the appliance by a person 
responsible for their safety. Children should be 
supervised to ensure that they do not play with 
the appliance.

Please consult an authorised dealer or 
specialist to clean the internal parts, repair, 
install, remove, disassemble and reinstall the 
unit. Improper installation and handling will
cause leakage, electric shock or fi re.

Confi rm with authorised dealer or specialist on 
usage of any specifi ed refrigerant type. Using 
refrigerant type other than the specifi ed may 
cause product damage, burst and injury etc.

Do not use means to accelerate the defrosting 
process or to clean, other than those 
recommended by manufacturer.
Any unfi t method or using incompatible material 
may cause product damage, burst and serious 
injury.

Do not install the unit in a potentially explosive 
or fl ammable atmosphere.
Failure to do so could result in fi re.
Do not insert your fi ngers or other 
objects into the air conditioner indoor or 
outdoor unit, rotating parts may cause 
injury.

Do not touch the outdoor unit during lightning, it 
may cause electric shock.

Do not expose yourself directly to cold air for a 
long period to avoid excess cooling.

Do not sit or step on the unit, you may 
fall down accidentally.

Remote control

Do not allow infants and small children to play 
with the remote control to prevent them from 
accidentally swallowing the batteries.

Power supply

Do not use a modifi ed cord, 
joint cord, extension cord or 
unspecifi ed cord to prevent 
overheating and fi re.

  

To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other 

equipment.

• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or 

pulling out the power plug.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air outlet

Air outlet

ACXF55-28780_SS0720-0.indd   4

25/6/2020   11:10:07 AM

Содержание CS-RZ25WKRW

Страница 1: ...ckaged in the indoor unit and removed by the installer before installation Kindly consult authorised dealer for connectivity validity Operating Instructions Air Conditioner Model No Indoor Unit Outdoo...

Страница 2: ...time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET Flexibility to connect Single Split System or Multi Split System Air Conditioner to su...

Страница 3: ...nit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode AUTO HEAT COOL FAN DRY 1 Press OFF ON OFF ON to start stop the operation...

Страница 4: ...usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean...

Страница 5: ...d animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or...

Страница 6: ...taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants a...

Страница 7: ...12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a...

Страница 8: ...re 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenanc...

Страница 9: ...ected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operati...

Страница 10: ...with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refrigerant cylinde...

Страница 11: ...er of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the...

Страница 12: ...aving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO Upper direction Do not adjust the flap by hand Lateral direction For lateral direction it is manually adjustable as shown...

Страница 13: ...ll activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are availab...

Страница 14: ...em which HEAT mode has been locked if operation mode other than HEAT is selected the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Uni...

Страница 15: ...BT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT...

Страница 16: ...r filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dr...

Страница 17: ...ue to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Water flowing sound during operati...

Страница 18: ...select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units ar...

Страница 19: ...sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdo...

Страница 20: ...ows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Inst...