Panasonic CS-RZ25WKRW Скачать руководство пользователя страница 18

18

When...

The remote control is missing or a malfunction has occurred

AUTO

OFF/ON

1.Raise the front panel.
2.Press the button once to use in AUTO mode.
3. Press and hold the button until you hear 1 beep, then release to use in 

forced COOL mode.

4.Repeat step 3. Press and hold the button until you hear 2 beeps, then 

release to use in forced HEAT mode.

5.Press the button again to turn off.

The indicators are too bright

• To dim or restore the unit’s indicator brightness, press 

 and hold for 5 seconds.

 Conducting a seasonal inspection after extended non-use

• Check the remote control batteries.
• Check that there is no obstruction around the air inlet and outlet vents.
• Use Auto OFF/ON button to select COOL/HEAT operation. After 15 minutes of operation, it 

is normal to have the following temperature difference between the air inlet and outlet vents:  

COOL: 

8 °C / 14.4 °F

  

HEAT: 

14 °C / 25.2 °F

 The units are not going to be used for a long period of time

• Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to 

prevent mould growth.

• Turn off the power supply and unplug.
• Remove the remote control batteries.

NON SERVICEABLE CRITERIAS

TURN OFF THE POWER SUPPLY AND UNPLUG then please consult an authorised 
dealer when in following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.

Troubleshooting

ACXF55-28780_SS0720-0.indd   18

25/6/2020   11:10:10 AM

Содержание CS-RZ25WKRW

Страница 1: ...ckaged in the indoor unit and removed by the installer before installation Kindly consult authorised dealer for connectivity validity Operating Instructions Air Conditioner Model No Indoor Unit Outdoo...

Страница 2: ...time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET Flexibility to connect Single Split System or Multi Split System Air Conditioner to su...

Страница 3: ...nit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode AUTO HEAT COOL FAN DRY 1 Press OFF ON OFF ON to start stop the operation...

Страница 4: ...usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean...

Страница 5: ...d animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or...

Страница 6: ...taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants a...

Страница 7: ...12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a...

Страница 8: ...re 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenanc...

Страница 9: ...ected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operati...

Страница 10: ...with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refrigerant cylinde...

Страница 11: ...er of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the...

Страница 12: ...aving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO Upper direction Do not adjust the flap by hand Lateral direction For lateral direction it is manually adjustable as shown...

Страница 13: ...ll activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are availab...

Страница 14: ...em which HEAT mode has been locked if operation mode other than HEAT is selected the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Uni...

Страница 15: ...BT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT...

Страница 16: ...r filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dr...

Страница 17: ...ue to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Water flowing sound during operati...

Страница 18: ...select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units ar...

Страница 19: ...sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdo...

Страница 20: ...ows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Inst...

Отзывы: