13.5 Airflow Direction
There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
13.5.1
Vertical Airflow
13.5.1.1 CU-RE9SKUA CU-RE12SKUA
Operation Mode
Airflow Direction
Vane angle (°)
1
2
3
4
5
Heating
Auto with Heat Exchanger
Temperature
A
20
B
57
C
32
Manual
20
32
45
57
68
Cooling
Auto
20 ~ 45
Manual
20
26
32
37
45
Soft Dry
Auto
20 ~ 45
Manual
20
26
32
37
45
13.5.1.2
CU-RE18SKUA CU-RE24SKUA
Operation Mode
Airflow Direction
Vane angle (°)
1
2
3
4
5
Heating
Auto with Heat Exchanger
Temperature
A
20
B
45
C
32
Manual
20
32
45
57
68
Cooling
Auto
20 ~ 45
Manual
20
26
32
37
45
Soft Dry
Auto (Anti-Dew Control)
20 ~ 45
Manual (Anti-Dew Control)
20
26
32
37
45
Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane
will shift to close position.
Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
140°
Close position
0°
122°F
8
6°F
96.
8
°F
136.4°F
C
B
A
Indoor Heat Exchanger
Temperat
u
re
1
2
3
4
5
Side View
Fig
u
re 2
Fig
u
re 1
13.5.2
Horizontal Airflow (CU-RE9SKUA CU-RE12SKUA)
The horizontal airflow direction louvers can be adjusted manually by hand.
Содержание CS-RE9SKUA
Страница 111: ...111 Figure 19 Figure 20...