129
20.11.2 CS-RE18SKUA CU-RE18SKUA CS-RE24SKUA CU-RE24SKUA
20.11.2.1 Cooling
Capacity
Cooling
Correction Factor
Pipe Length (m/ft)
0.95
0.97
0.99
1.01
1.03
2
(6.6)
3
(9.8)
4
(13.1)
5
(16.4)
6
(19.7)
7
(23)
8
(26.2)
9
(29.5)
10
(33)
11
(36.1)
12
(39.4)
13
(42.6)
14
(45.9)
15
(49.2)
16
(52.5)
17
(55.7)
18
(59)
19
(62.3)
20
(65.6)
21
(68.9)
Piping length
Capacity (kW)
3 (9.8)
1.0222
7.5 (24.6)
1.0000
10 (32.8)
0.9950
15 (49.2)
0.9861
20 (65.6)
0.9807
20.11.2.2 Heating
Capacity
Heating
Correction Factor
0.95
0.96
0.97
0.98
0.99
1.00
1.01
1.02
Pipe Length (m/ft)
2
(6.6)
3
(9.8)
4
(13.1)
5
(16.4)
6
(19.7)
7
(23)
8
(26.2)
9
(29.5)
10
(33)
11
(36.1)
12
(39.4)
13
(42.6)
14
(45.9)
15
(49.2)
16
(52.5)
17
(55.7)
18
(59)
19
(62.3)
20
(65.6)
21
(68.9)
Piping length
Capacity (kW)
3 (9.8)
1.0089
7.5 (24.6)
1.0000
10 (32.8)
0.9964
15 (49.2)
0.9861
20 (65.6)
0.9773
Note: The graphs show the factor after added right amount of additional refrigerant.