![Panasonic CS-PE12DKE Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/panasonic/cs-pe12dke/cs-pe12dke_service-manual_1507911004.webp)
Indoor Unit
Force Cooling Operation
When the remote control cannot be used or
for repairing and testing ,please use this
button.
Power Switch ON/OFF
Operation Indication Lamps
Power (green)
Timer(orange)
Lights up in operation;
Blinks during Hot Start
operation and
determining Auto
Operation mode
Operation Mode
Cooling/Heating/Soft Dry /Auto Operation
Time Delay Safety Control
The unit will restart operation in 3-4
minutes after each pause.
4
Keep pressing this button for 5 seconds to start
the force cooling operation.
Auto Switch
Button
Air quality
Green
Orange
Red
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Warm Booting Control
Indoor fan starts running when indoor
piping
reaches 19
or above.
temperature
High,Med+, Med, Med-,Low
Auto Fan Speed
Indoor Fan Speed Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Five Manual Airflow Direction Control
Airflow Direction Control
Delayed On-timer Control
For cooling or soft dry mode, the unit
starts 15 minutes before the set time with
the remote control, but for heating mode
30 minutes before the set time.
CS-PE9DKE / CU-PE9DKE / CS-PE12DKE / CU-PE12DKE
Force Heating Operation
Keep pressing this button for 8 seconds to start
the force heating operation.
Signal Receiving Sound
Keep pressing this button for 16 seconds to turn
off or turn on the signal receiving sound or
H14 Abnormality Detection Mode.
Light up in Timer Setting.
Blinks in Self Diagnosis Control
Automatic Restart Control
Operation is restarted after power failure
at previous setting mode.
Different Remote Controlling Setting
Keep pressing this button for11 to change
different remote controlling setting(A
B)
Mode.