The airflow direction will change as below by pressing the AIR SWING button.
AUTO
Airflow Direction:
Display of Diagnosis
Refer to Diagnosis section.
Change the Code of Remote Controller
Change the code of remote controller by joining or cutting jump wire on the remote controller and indoor PCB.
Four codes(A,B,C,D) can be selected.
J
B
Inside the battery box of
remote controller.
On indoor PCB
J----B
Indoor PCB
Short
Open
A
B
C
D
Short
Open
Air Swing Button
8.2 Operation and Display of Indoor Unit
AUTO Operation Switch
SW ON
AUTO
Operation
Forced
COOL
Forced
HEAT
Various Setting
Mode
Individual
Counter-action
Number of beep
1
2
3
4
5s
8s
11s
16s
21s
Function
1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
4. When the switch is pressed between 11 to 16 seconds and together with the signal from the remote controller,
the unit can be changed to different controlling setting .
5. When the switch is pressed between 16 to 21 seconds, either H14 error detection selection mode or remote
controller ’s signal receiving sound can be cancelled or turned on.
6. If the intake air temperature is less than 16
and the Forced Cooling is activated, because the prior operation
mode is heating, the compressor will stop for 3 minutes to start the Forced Cooling operation.
CS-PE9DKE / CU-PE9DKE / CS-PE12DKE / CU-PE12DKE