Airflow Direction Control
Airflow Direction Auto-control
The left and right airflow direction louver can be adjusted manually.
When set at airflow direction auto-control with remote control,the louver swings up and down as shown in the table below.
The louver does not swing when the indoor fan stops during operation.
When stop the unit with remote control,the discharge vent is closed with the louver.
Cooling
Soft dry
Operating Mode
Determining operation
mode
Manual
Auto
1
2
3
4
5
12
17
26
32
36
o
o
o
o
o
12 ~36
o
o
9
o
Airflow direction manual control
Angles Of Airflow Direction Louver
Notes:
In cooling or soft dry mode operation
If the compressor continues to operate for 60 minutes ,and the louver direction is at No 5,the fan speed is below Med, the intake
air temperature is below 29
and continues to change between 2
for 30 minutes ,the louver direction will be at No 2 in order
to prevent dew around the discharge vent.
When the airflow direction set button is pressed,the automatic airflow is released and the airflow direction louver
moves up and down as shown in thetable below. The louver can be stopped by releasing the button at the desired
position.
When the remote control is used to stop the operation,the discharge vent is closed with airflow direction louver.