40
11.7 CONNECTING THE CABLE TO THE INDOOR UNIT
Remove the mounting screw, remove the control
box cover, and then connect the wires by
following the procedure given in the illustration.
Connecting cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 4 x 1.5 mm
2
flexible cord, type
designation 60245 IEC 57 or heavier cord.
Secure the connecting cable onto the control
board with the holder (clamper).
Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s
respectively.
Earth wire shall be Yellow/Green (Y/G) in colour
and longer than other AC wires for safety reason.
11.7.1 WIRE STRIPPING AND CONNECTING REQUIREMENT