How to install the air clean filter

The air clean filter needs to be installed behind the anti-mold filter.

Open the front panel and remove the anti-mold filters, then install 

the air clean filter in the position shown in the figure. After that, 

remount the anti-mold filters and close the front panel.

How to clean the air clean filter

• In general, the filter should be sucked to remove dust in low fan 

speed of a vacuum cleaner once every three months.

• If there is heavily grime on the filter, soak the filter in lukewarm 

water with neutral detergent diluted 1:500 for 1 to 2 minutes then 

wash it.

• Rinse the filter in clean water, then let it dry on the towel in room 

temperature.

• Do not bend nor give excessive force onto the air clean filter.

• If the filter surface is heavily blocked with dirt or damaged, 

replace it with new one. Purchase a replacement filter at your 

local dealer. (model 

CZ-SA1U

)

Cleaning the main unit and remote controller

• Wipe clean using a soft, dry cloth.

• To remove stubborn dirt, moisten a cloth in warm water no hotter 

than 40 °C, wring thoroughly, and then wipe.

• The front panel can be removed in order to wash it with water.

Removing and remounting the front panel
1.

Open the front panel until it is nearly horizontal, grasp the 

sections near the front panel arms on both sides, and then pull 

forward to remove the front panel.

2.

Grasp the sections near the front panel arms on both sides, 

and hold the front panel so that it is nearly horizontal. Then 

push firmly until the arm shafts click into place. After closing the 

front panel, press firmly on the parts indicated by the arrows to 

securely fasten the panel in place.

Also refer to the figure that shows “How to replace the anti-

mold filter”.

Washing the front panel with water

• Clean the front panel gently using a soft sponge, or the like. 

Then wipe away any remaining moisture.

• Neutral detergent may be used to remove stubborn dirt. Then 

rinse thoroughly with water and wipe away any remaining 

moisture.

TROUBLESHOOTING (BEFORE 
CALLING FOR SERVICE)

If your air conditioner does not work properly, first check the 

following points before requesting service. If it still does not work 

properly, contact your dealer or service center.

OPERATING RANGE

The air conditioner is operable within the temperature ranges as 

listed below:

NOTE

When using a footstool or the like, be 
careful not to let it tip over.

Air clean filter

CAUTION

Trouble 

Possible Cause 

Remedy

Air conditioner does 

not run at all.

1. Power failure. 

1. Restore power.

2. Leakage circuit 

breaker tripped.

2. Contact service 

center.

3. Line voltage is too 

low.

3. Consult your 

electrician or 

dealer.

4. Batteries in remote 

controller have run 

down.

4. Replace batteries.

OPERATION lamp 

blinks and air 

conditioner does not 

operate.

Trouble in system.

Contact service 

center.

Compressor runs but 

soon stops.

Obstruction in front of 

condenser coil.

Remove obstruction.

Poor cooling (or 

heating) 

performance.

1. Dirty or clogged air 

filter.

1. Clean air filter to 

improve airflow.

2. Heat source or 

many people in 

room.

2. Eliminate heat 

source if possible.

3. Doors and/or 

windows are open.

3. Shut them to keep 

the heat (or cold) 

out.

4. Obstacle near air 

intake or air 

discharge port.

4. Remove it to 

ensure good 

airflow.

5. Thermostat is set 

too high for cooling 

(or too low for 

heating).

5. Set the 

temperature lower 

(or higher).

6. (Outdoor 

temperature is too 

low for heating.) 

6. (Consult your 

dealer or try to use 

another heat 

appliance.)

Clicking sound is 

heard from the air 

conditioner.

In heating or cooling 

operation, any plastic 

parts may expand or 

shrink due to a 

sudden temperature 

change. In this event, 

a clicking sound may 

occur.

This is normal, and 

the sound will soon 

disappear.

OPERATION lamp 

lights but outdoor unit 

will not run.

The use of cellular 

phones near the air 

conditioner may 

cause disturbance to 

its normal operation.

1. Turn off the power 

then restart the air 

conditioner after a 

while.

2. Consult your 

dealer.

Temperature  Indoor air 

temperature 

Outdoor air 

temperature

COOLING Max. 

32 °C DB / 

23 °C WB 

43 °C DB

Min. 

19 °C DB / 

14 °C WB 

–10 °C DB

HEATING

Max. 

27 °C DB

24 °C DB / 

18 °C WB

Min. 

16 °C DB

– DB/ –15 °C WB

01_85264181224000_EN.fm  Page 17  Monday, January 30, 2012  12:30 PM

Содержание CS-ME18NKE

Страница 1: ...funcionamiento y guárdelas para futuras consultas FRANÇAIS 38 55 Avant d utiliser l appareil lisez ce mode d emploi dans son intégralité et conservez le pour toute référence ultérieure DEUTSCH 56 73 Bevor Sie das Gerät in Betrieb nehmen lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf ITALIANO 74 91 Prima di utilizzare l unità leggere ...

Страница 2: ...ortable This system prevents any cold blasts at the beginning while the heat pump is warming up or even defrosting Automatic Restart Function for Power Failure Even when power failure occurs preset programmed operation can be reactivated once power resumes High Power Operation If not in Auto Operation the unit operates at maximum output for 30 minutes regardless of the desired temperature The fan ...

Страница 3: ...of the electric supply in your home or office is the same as the voltage shown on the nameplate Avoid To protect the air conditioner from heavy corrosion avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa ELECTRICAL REQUIREMENTS 1 All wiring must conform to the local electrical codes Consult your dealer or a qualified electrician for...

Страница 4: ...ir Refrigerant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not insert your fingers or other objects into the ai...

Страница 5: ...collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By disposing of these products and batteries correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of ...

Страница 6: ... connected by copper tubes through which refrigerant gas flows Drain Hose Moisture in the room condenses and drains off through this hose Outdoor Condensing Unit The outdoor unit contains the compressor fan motor heat exchanger coil and other electrical components INDOOR UNIT Air Intakes Remote Controller Air Outlet Refrigerant Tubes Drain Hose OUTDOOR UNIT Air Outlet REMOTE CONTROL receiver This ...

Страница 7: ...Timer ON Timer OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation Displayed when setting timer Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when the time display...

Страница 8: ... follows NOTE SWEEP CANCEL button SENSOR button When you press this button use a small tipped object such as a ballpoint pen the mark will appear at the display And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly If the remote controller is located near a heat source such as a space heater or in direct sunlight pr...

Страница 9: ...air conditioner makes the room cooler When multiple indoor units are used and units in other rooms are already operating they will be set to the same mode of operation as the operating indoor units NOTE NIGHT SETBACK button For details see 4 Night Setback Mode When you press this button in the HEAT DRY or COOL mode the mark appears in the display and the remote controller will automatically adjust...

Страница 10: ...er press the ON OFF operation button at the mounting location to make sure that the air conditioner operates from that location The indoor unit should make a beeping sound to indicate that it has received the signal To take out the remote controller pull it forward WHEN HOLDING THE REMOTE CONTROLLER When using the remote controller and during air conditioner operation the transmitter on the remote...

Страница 11: ...DE selector button and select the desired mode For heating operation For dehumidifying operation For cooling operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature The set temperature appears in the display for only 3 seconds Adjustable temperature range STEP 4 Set the FAN SP...

Страница 12: ...unit is already operating with a very low airflow the fan sound may not change even if the QUIET button is pressed NOTE When the night setback mode is selected the air conditioner automatically raises the temperature setting 1 C when 30 minutes have passed after the selection was made and then another 1 C after another 30 minutes have passed regardless of the indoor temperature when night setback ...

Страница 13: ...r temperature is very low If sufficient heat cannot be obtained with this air conditioner use another heating appliance together with it Defrosting When the outdoor temperature is low frost or ice may form on the heat exchanger coil reducing heating performance When this happens a microcomputer defrosting system operates At the same time the fan on the indoor unit stops and the OPERATION lamp ligh...

Страница 14: ...d OFF timer are set to the same time the timer operates as if it is turned off NOTE Operation Indication 1 Press the CLOCK button once if the time indicator is not flashing The time indication alone flashes 2 Press the Advance Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CL...

Страница 15: ...rs and any other openings closed ADJUSTING THE AIRFLOW DIRECTION 1 Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right When the humidity is high the vertical vanes should be in the front position during the cooling or dehumidifying operation If the vertical vanes are positioned all of the way to the right or left condensation may begi...

Страница 16: ... the filter in lukewarm soapy water rinse it in clean water and dry it How to replace the anti mold filter 1 Insert the top of the anti mold filter align the two protrusions with the center hook at bottom then mount the filter into place 2 Press the locations marked by the arrows and close the front panel Air Clean Filter The air clean filter removes dust and dirt from the air and reduces odors an...

Страница 17: ...e away any remaining moisture TROUBLESHOOTING BEFORE CALLING FOR SERVICE If your air conditioner does not work properly first check the following points before requesting service If it still does not work properly contact your dealer or service center OPERATING RANGE The air conditioner is operable within the temperature ranges as listed below NOTE When using a footstool or the like be careful not...

Страница 18: ...ound Pressure Level H M L dB A 40 37 34 43 40 37 Unit Dimensions H W D Indoor unit Include panel mm 298 0 1 065 0 234 0 298 0 1 065 0 234 0 Net Weight kg 12 0 12 0 Model No Outdoor Unit CU 5E34NBE Power Source Single phase 220 230 240 V 50 Hz Cooling Capacity kW 10 00 3 50 11 50 BTU h 34 100 11 900 39 200 Heating Capacity kW 12 00 4 00 14 50 BTU h 40 900 13 600 49 500 Operation Sound Cooling Opera...

Страница 19: ...el 7 1 R410A NICHT IN DIE AUSSENLUFT ABLASSEN R410A IST EIN FLUORIERTES TREIBHAUSGAS DAS IM KYOTO PROTOKOLL ENTHALTEN IST UND EIN ERDERWÄRMUNGSPOTENTIAL GWP VON 1975 AUFWEIST Osservanza delle richieste dell Articolo 7 1 delle regolamentazioni 842 EC 2006 NON DISPERDERE R410A NELL ATMOSFERA L R410A È UN GAS FLUORATO CAUSA DI EFFETTO SERRA E COPERTO DAL PROTOCOLLO DI KYOTO CON UN POTENZIALE DI RISCA...

Страница 20: ...rsuant to at the directive 2004 108 EC article 9 2 Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany Printed in China ID0212 0 ...

Отзывы: