2-4. Presence of 

fi

 re extinguisher

• If any hot work is to be conducted on the 

refrigeration equipment or any associated 
parts, appropriate fi re extinguishing 
equipment shall be available at hand.

• Have a dry powder or CO

2

 fi re extinguisher 

adjacent to the charging area.

2-5. No ignition sources

• No person carrying out work in relation to a 

refrigeration system which involves exposing 
any pipe work that contains or has contained 
fl ammable refrigerant shall use any sources 
of ignition in such a manner that it may lead 
to the risk of fi re or explosion. He/She must 
not be smoking when carrying out such work.

• All possible ignition sources, including 

cigarette smoking, should be kept suffi ciently 
far away from the site of installation, 
repairing, removing and disposal, during 
which fl ammable refrigerant can possibly be 
released to the surrounding space.

• Prior to work taking place, the area around 

the equipment is to be surveyed to make 
sure that there are no fl ammable hazards or 
ignition risks.

• “No Smoking” signs shall be displayed.

2-6. Ventilated area

• Ensure that the area is in the open or that it 

is adequately ventilated before breaking into 
the system or conducting any hot work.

• A degree of ventilation shall continue during 

the period that the work is carried out.

• The ventilation should safely disperse any 

released refrigerant and preferably expel it 
externally into the atmosphere.

2-7. Checks to the refrigeration equipment

• Where electrical components are being 

changed, they shall be fi t for the purpose 
and to the correct specifi cation.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• The following checks shall be applied to 

installations using fl ammable refrigerants.

 

- The charge size is in accordance with 

the room size within which the refrigerant 
containing parts are installed.

 

- The ventilation machinery and outlets are 

operating adequately and are not obstructed.

 

- If an indirect refrigerating circuit is being 

used, the secondary circuit shall be 
checked for the presence of refrigerant.

 

- Marking to the equipment continues to be 

visible and legible. Markings and signs that 
are illegible shall be corrected.

 

- Refrigeration pipe or components are 

installed in a position where they are unlikely 
to be exposed to any substance which may 
corrode refrigerant containing components, 
unless the components are constructed of 
materials which are inherently resistant to 
being corroded or are properly protected 
against being so corroded.

2-8. Checks to electrical devices

• Repair and maintenance to electrical 

components shall include initial safety 
checks and component inspection 
procedures.

• Initial safety checks shall include but not 

limit to:-

 

- That capacitors are discharged: this 

shall be done in a safe manner to avoid 
possibility of sparking.

 

- That there no live electrical components 

and wiring are exposed while charging, 
recovering or purging the system.

 

- That there is continuity of earth bonding.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• If a fault exists that could compromise safety, 

then no electrical supply shall be connected 
to the circuit until it is satisfactorily dealt with.

• If the fault cannot be corrected immediately 

but it is necessary to continue operation, an 
adequate temporary solution shall be used.

• The owner of the equipment must be 

informed or reported so all parties are 
advised thereinafter.

3. Repairs to sealed components

• During repairs to sealed components, all 

electrical supplies shall be disconnected 
from the equipment being worked upon prior 
to any removal of sealed covers, etc.

• If it is absolutely necessary to have an 

electrical supply to equipment during 
servicing, then a permanently operating 
form of leak detection shall be located at the 
most critical point to warn of a potentially 
hazardous situation.

• Particular attention shall be paid to the 

following to ensure that by working on 
electrical components, the casing is not 
altered in such a way that the level of 
protection is affected.
This shall include damage to cables, 
excessive number of connections, terminals 
not made to original specifi cation, damage to 
seals, incorrect fi tting of glands, etc.

• Ensure that apparatus is mounted securely.
• Ensure that seals or sealing materials have 

not degraded such that they no longer serve 
the purpose of preventing the ingress of 
fl ammable atmospheres.

• Replacement parts shall be in accordance 

with the manufacturer’s specifi cations.

NOTE: The use of silicon sealant may inhibit 
the effectiveness of some types of leak 
detection equipment.
Intrinsically safe components do not have to 
be isolated prior to working on them.

ACXF55-1918̲OL.ai   7   6/1/2018   1:12:43 PM

ACXF55-1918̲OL.ai   7   6/1/2018   1:12:43 PM

Содержание CS-LU12UKYRN Series

Страница 1: ...KYMNS series CU LU18UKYMNA series ACXF55 19180 AC English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C SLEEP SLEEP POWERFUL POWERFUL nanoe G nanoe G PURIFIER PURIFIER POWER POWER ACXF55 1918 OL ai 1 6 1 20...

Страница 2: ...ACXF55 1918 OL ai 2 6 1 2018 1 12 42 PM ACXF55 1918 OL ai 2 6 1 2018 1 12 42 PM ...

Страница 3: ...ontrol within 8 m from the remote control receiver of the indoor unit FAN DRY Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 To confirm Press SET or CLOCK again Please note that the OFF indication is as follows FAN nanoe G CHECK CHECK ACXF55 1918 OL ai 3 6 1 2018 1 12 42 PM ACXF55 1918 OL ai 3 6 1 2018 1 12 42 PM ...

Страница 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Страница 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Страница 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Страница 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Страница 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Страница 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Страница 10: ... Con in Fan Only mode Unit operates without running compressor with IDU fan running as per remote setting fan speed and air flow direction Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode SLEEP Room temperature 23 C above Below 23 C 25 C 22 C Standard setting temperature ACXF55 1918 OL ai 10 6 1 2018 1 12 43 PM ACXF55 1918 OL ai 10 6 1 2018 1 12 43 PM ...

Страница 11: ...o cancel ON or OFF timer press or then press If timer is cancelled manually or due to power failure you can restore the timer again by pressing or then press The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based...

Страница 12: ...ith water For seasonal inspection after extended non use Checking of remote control batteries No obstruction at air inlet and air outlet vents Use Auto OFF ON button to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alter...

Страница 13: ...sh 13 Troubleshooting Cleaning instructions Troubleshooting The unit stops and some alpha numeric codes appear on IDU display ACXF55 1918 OL ai 13 6 1 2018 1 12 45 PM ACXF55 1918 OL ai 13 6 1 2018 1 12 45 PM ...

Страница 14: ...ow for Full Load and for Half Load Setting Testing Guidelines Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 POWER TIMER nanoe G PURIFIER SLEEP POWERFUL POWER TIMER nanoe G PURIFIER SLEEP POWERFUL Auto OFF ON Button Indication for Half load Indic...

Страница 15: ...r http www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental br...

Страница 16: ...al ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 1918 OL ai 16 6 1 2018 ...

Отзывы: