FAN

CHECK

(Green)

(Orange)

(Blue)

(Orange/Green)

(Temperature

 display)

Press the button to turn on.

SLEEP/

SLEEP/
POWERFUL

POWERFUL

nanoe-G

nanoe-G
PURIFIER

PURIFIER

POWER

POWER

nanoe-G

10

 

FAN - To operate Air-Con in “Fan Only” mode 

Unit operates without running compressor with 
IDU fan running as per remote setting fan speed
and air flow direction. 

* Indoor unit temp. display will show set temp. for 
  AUTO,COOL & DRY mode and room temp. for FAN 
  mode.

SLEEP

Room temperature

23 °C & above

Below 23 °C

25 °C
22 °C

Standard setting 

temperature

ACXF55-1918̲OL.ai   10   6/1/2018   1:12:43 PM

ACXF55-1918̲OL.ai   10   6/1/2018   1:12:43 PM

Содержание CS-LU12UKYRN Series

Страница 1: ...KYMNS series CU LU18UKYMNA series ACXF55 19180 AC English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C SLEEP SLEEP POWERFUL POWERFUL nanoe G nanoe G PURIFIER PURIFIER POWER POWER ACXF55 1918 OL ai 1 6 1 20...

Страница 2: ...ACXF55 1918 OL ai 2 6 1 2018 1 12 42 PM ACXF55 1918 OL ai 2 6 1 2018 1 12 42 PM ...

Страница 3: ...ontrol within 8 m from the remote control receiver of the indoor unit FAN DRY Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 To confirm Press SET or CLOCK again Please note that the OFF indication is as follows FAN nanoe G CHECK CHECK ACXF55 1918 OL ai 3 6 1 2018 1 12 42 PM ACXF55 1918 OL ai 3 6 1 2018 1 12 42 PM ...

Страница 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Страница 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Страница 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Страница 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Страница 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Страница 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Страница 10: ... Con in Fan Only mode Unit operates without running compressor with IDU fan running as per remote setting fan speed and air flow direction Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode SLEEP Room temperature 23 C above Below 23 C 25 C 22 C Standard setting temperature ACXF55 1918 OL ai 10 6 1 2018 1 12 43 PM ACXF55 1918 OL ai 10 6 1 2018 1 12 43 PM ...

Страница 11: ...o cancel ON or OFF timer press or then press If timer is cancelled manually or due to power failure you can restore the timer again by pressing or then press The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based...

Страница 12: ...ith water For seasonal inspection after extended non use Checking of remote control batteries No obstruction at air inlet and air outlet vents Use Auto OFF ON button to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alter...

Страница 13: ...sh 13 Troubleshooting Cleaning instructions Troubleshooting The unit stops and some alpha numeric codes appear on IDU display ACXF55 1918 OL ai 13 6 1 2018 1 12 45 PM ACXF55 1918 OL ai 13 6 1 2018 1 12 45 PM ...

Страница 14: ...ow for Full Load and for Half Load Setting Testing Guidelines Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 POWER TIMER nanoe G PURIFIER SLEEP POWERFUL POWER TIMER nanoe G PURIFIER SLEEP POWERFUL Auto OFF ON Button Indication for Half load Indic...

Страница 15: ...r http www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental br...

Страница 16: ...al ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 1918 OL ai 16 6 1 2018 ...

Отзывы: