Emergency operation
SENSOR DRY
During DRY operation, the system adjusts the room
temperature and fan speed according to the conditions in the
room, in order to maintain a comfortable room environment.
SENSOR DRY operation
• DRY operation is as shown in the figure below.
PAM- control
• In order to further improve inverter performance, control is
switched between PWM control at low operation speeds, and
PAM control at high operation speeds, making the most
effective use of power.
The compressor operation frequency varies.
The indoor fan operates with 1/f fluctuation.
The compressor operates at a low operating frequency.
The indoor fan operates with 1/f fluctuation.
• Monitoring operation takes place when the room temperature
is below 59°F
(
15°C), or more than 5°F
(
3°C) below the set
temperature.
• When the monitoring range is entered, the compressor stops,
and the indoor fan operates with 1/f fluctuation.
DRY A
DRY B
Monitor
Conditions are monitored at all
times when the room temperature
is below 59°F(15°C).
Load
COOL zone
A zone
B zone
Emergency operation is available when the remote
controller malfunctions, has been lost, or otherwise
cannot be used.
• The set temperature is 4°F(2°C) below the detected room
temperature in the case of cooling operation. The flap and
fan speed settings are AUTO.
(GREEN) (Lamp
Off)
COOL
STOP
To operate the system, press the OPERATION button,
which is also used as the receiver, below the unit display.
Each time this button is pressed, the OPERATION lamp
changes color to indicate the type of operation. Select the
desired type of operation.
7. FUNCTIONS
7-1. Operation Functions
28
Содержание CS-KS18NB4UW & CZ-18BT1U + CU-KS18NKU
Страница 39: ......
Страница 40: ...Operating Instructions APPENDIX A 852 6 4181 216 00 1 CS MKS9NB4U CZ 18BT1U CS MKS12NB4U CZ 18BT1U A 1 ...
Страница 57: ......
Страница 58: ...Operating Instructions CS KS18NB4UW CZ 18BT1U 852 6 4181 211 00 1 APPENDIX B A 2 ...
Страница 94: ...Operating Instructions CZ RD515U 852 6 4181 230 00 1 APPENDIX D A 4 ...
Страница 105: ......
Страница 106: ...A 5 INSTALLATION INSTRUCTIONS CZ RD515U 852 6 4190 592 00 0 APPENDIX E ...
Страница 111: ......
Страница 112: ...DC1111 0 ...