45
12.11.1. Signal Detection
• Human Activity sensor will turns on according to infrared sensors signal detection.
* Indicator ON, Indicator OFF
• However, once the Human Activity Indicator is ON, it will maintain ON status for 5 seconds. If there is no signal detection from
either infrared sensor, the final display condition will be kept until absence status.
12.11.2. Information Log
• The signal from Infrared sensors will be log to human activity database for further analysis.
12.11.3. Area of Living Classification Judgment
• The system is able to judge area of living according to human activity database, classified as following:
- Living Area – In front of television, dining table, etc.
- Walkway – Human detection is relatively less.
- Non-Living Area – near windows, wall, etc.
12.11.4. Human Position Analysis
• According to Area of Living, frequency of activity and indoor unit intake temperature, the system will analyze the human position
away from the indoor unit.
12.11.5. Target Area and Position Judgment
• The system will judge the indoor unit installation position according to human activity Non-Living Area:
- Non-Living Area at Position A – Indoor unit installed at left side of the room.
- Non-Living Area at Position C – Indoor unit installed at right side of the room.
- Other than above – Indoor unit installed at center of the room.
• Every 4 hours, the Target Area and Position Judgment will restart.
12.11.6. Human Activity Level Judgment
• Human Activity Level is judged based on the frequency of pulses detected by the infrared sensors within a timeframe. The
activity level will be categorized into High, Normal, Low level.
• When a pulse is detected within this timeframe, the status of human presence is judged.
• When there is no signal detection continues for 20 minutes or more, the status of human absence is judged.
Signal Detection
Possible detected human
position area
Human Activity Sensor
Sensor 1
Sensor 2
Left
Center
Right
1
0
C
0
1
A
1
1
B
A & C
B & C
A & C
A, B & C
0
0
-
Содержание CS-E24MKES
Страница 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Страница 11: ...11 5 2 Outdoor Unit ...
Страница 12: ...12 6 Refrigeration Cycle Diagram ...
Страница 13: ...13 7 Block Diagram ...
Страница 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Страница 15: ...15 8 2 Outdoor Unit 8 2 1 CU E24MKE ...
Страница 16: ...16 8 2 2 CU E28MKE ...
Страница 17: ...17 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 18: ...18 9 2 Outdoor Unit 9 2 1 CU E24MKE ...
Страница 19: ...19 9 2 2 CU E28MKE ...
Страница 20: ...20 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 22: ...22 10 1 6 Comparator Printed Circuit Board 10 1 7 Human Activity Sensor Printed Circuit Board ...
Страница 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Страница 24: ...24 10 2 2 Power Printed Circuit Board ...
Страница 92: ...92 16 1 3 To remove power electronic controller ...
Страница 93: ...93 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Страница 94: ...94 16 1 6 To remove cross flow fan and indoor fan motor ...
Страница 95: ...95 ...
Страница 109: ...109 18 2 Outdoor Unit 18 2 1 CU E24MKE ...