8.2. Soft Dry Mode Operation
- The unit starts cooling operation until the room temperature
reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
- During Soft Dry operation, the Indoor Fan operates with Lo speed.
- Once room temperature reaches below Soft Dry OFF temperature,
Indoor Fan, Compressor and Outdoor Fan Stop for 6 minutes.
Time Delay Safety Control
- Once the compressor stops, it will not start for 3 minutes during
Cooling operation.
Anti-Freezing Control
- Same as Anti-Freezing Control for Cooling Mode operation. (For