– 39 –
MAC9512086C2
CS-A181KE
Technical Data
L
L
L
L
L
Operation characteristics
CS-A181K / CU-A181K
• Piping Length Characteristic (Cooling)
•
Cooling Characteristic
•
Heating Characteristic
• Piping Length Characteristic (Heating)
PIPING LENGTH (m)
5
25
15
20
10
12.0
11.0
10.0
9.0
14.0
13.5
13.0
0.44
0.43
0.42
0.41
5.2
5.0
4.8
4.6
4.4
220V
240V
I: Q:
Current (A)
-
Cooling Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
[Condition] Room temperature: 27/19
°
C
Outdoor air temperature: 35/24
°
C
Cooling operation: High fan
I
Q
O
LP
30 32 34 36 38 40 42 44
OUTDOOR ROOM TEMPERATURE (
°
C)
[Condition] Room temperature: 27/19
°
C
Cooling operation: High fan
Piping length: 7.5 m
13
12
11
10
9
14.0
13.5
13.0
12.5
12.0
0.46
0.45
0.44
0.43
0.42
5.6
5.4
5.2
5.0
4.8
4.6
220V
240V
I: Q:
Current (A) Cooling Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
I
LP
Q
O
-6 -4 -2 0 2 4 6 8
OUTDOOR AIR TEMPERATURE (
°
C)
[Condition] Room temperature: 20
°
C
Heating operation:High fan
Piping length: 7.5 m
13
12
11
10
9
44
42
40
38
36
1.8
1.7
1.6
1.5
1.4
1.3
6.0
5.5
5.0
4.5
4.0
220V
240V
I: Q:
Current (A) Heating Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
I
LP
Q
O
12.0
11.5
11.0
10.5
43.0
42.5
42.0
41.5
1.84
1.82
1.80
1.78
1.76
1.74
1.72
6.2
6.1
6.0
5.9
5.8
PIPING LENGTH (m)
5
25
15
20
10
220V
240V
I: Q:
Current (A)
-
Heating Capacity (kW)
-
LP: O: Outlet
Gas Side Piping Pressure (MPa)
Air Temperature (
°
C)
[Condition] Room temperature: 20
°
C
Outdoor temperature: 7/6
°
C
Heating operation: High fan
I
LP
Q
O
Untitled-4
6/21/00, 10:40 AM
39