– 15 –
MAC9512086C2
CS-A181KE
Operation Details
2) Soft Dry Mode Operation
• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
• During Soft Dry operation, the Indoor Fan operates with SLo speed.
• Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan
Stop for 6 minutes.
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
• Fan speed rotates at SLo speed.
• Deodorizing Control.
Time Delay Safety Control
Anti-Freezing Control
Indoor
Fan
COMP
stop
stop
stop
SLo
SLo
SLo
ON
ON
OFF
40"
40"
6'
Automatic Fan Speed Mode
Untitled-9
6/21/00, 10:18 AM
15