14.10 4-Way Valve Control
•
4-way valve always on during Heating operation. (except deicing operation)
•
When the unit is switched off by remote control during Heating operation, the 4-way valve stay at Heating
position for 5 minutes.
•
This is to prevent the refrigerant flow process sound for being occur.
14.11 Outdoor Fan Motor Control
•
When compressor stops (reaches room temperature), outdoor fan will operate for 30 seconds (forced operation).
•
This is to release the heat and to obtain the lowest pressure as fast as possible.
14.12 Hot Start Control
•
Hot start control is to prevent cool air discharge into room when heating operating starts.
•
Hot start is executed after heating operation starts and deice operation is completed.
•
Indoor fan control during hot start is shown below:
Indoor Pipe Temperature
Indoor Fan
≤
30°C
OFF
30°C < t
≤
34°C
SLo
t
≥
34°C
Lo-
•
When indoor pipe temperature over 34°C or maximum 240 seconds, hot start is completed.
•
During hot start and for 30 seconds after hot start completed, intake thermostat is ignored and no Thermo OFF.
14.13 Cold Draft Prevention Control
•
This operation is to prevent the Cold Draft during Heating mode operation.
•
The operation will start when compressor OFF (Thermo OFF) during Heating operation.
•
For the first 30 sec. from compressor OFF (Thermo OFF), Indoor fan speed will operate accordingly to the Indoor
heat exchanger temperature as shown below:
•
After 30 sec. from compressor OFF (thermo OFF), Indoor fan will run at SSLo speed only.
•
Anti Cold Draft Control will stop when:
o
Intake temperature < set temperature. (Time Delay Safety Control 4 minutes waiting is valid)
o
30 Minutes Time Save Control activates.
Содержание CS-A12PKD
Страница 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Страница 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS A9PKD CS A12PKD...
Страница 14: ...14 5 1 2 CS A18PKD CS A24PKD CS A28PKD...
Страница 15: ...15 5 2 Outdoor Unit 5 2 1 CU A9PKD 5 2 2 CU A12PKD...
Страница 16: ...16 5 2 3 CU A18PKD...
Страница 17: ...17 5 2 4 CU A24PKD CU A28PKD...
Страница 18: ...18 6 Refrigeration Cycle Diagram 6 1 CS A9PKD CU A9PKD CS A12PKD CU A12PKD...
Страница 19: ...19 6 2 CS A18PKD CU A18PKD CS A24PKD CU A24PKD CS A28PKD CU A28PKD...
Страница 20: ...20 7 Block Diagram 7 1 CS A9PKD CU A9PKD...
Страница 21: ...21 7 2 CS A12PKD CU A12PKD...
Страница 22: ...22 7 3 CS A18PKD CU A18PKD CS A24PKD CU A24PKD...
Страница 23: ...23 7 4 CS A28PKD CU A28PKD...
Страница 28: ...28 9 Electronic Circuit Diagram 9 1 CS A9PKD CU A9PKD...
Страница 29: ...29 9 2 CS A12PKD CU A12PKD...
Страница 30: ...30 9 3 CS A18PKD CU A18PKD CS A24PKD CU A24PKD...
Страница 31: ...31 9 4 CS A28PKD CU A28PKD...
Страница 32: ...32 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board 10 1 1 1 CS A9PKD CS A12PKD...
Страница 34: ...34 10 1 4 Comparator Printed Circuit Board 10 1 5 Human Activity Sensor Printed Circuit Board...
Страница 40: ...40 11 2 5 Wire Stripping And Connecting Requirement...
Страница 48: ...48 12 2 5 Wire Stripping And Connecting Requirement...
Страница 55: ...55 13 2 2 Cooling Operation Time Diagram For CS A18PK CU A18PK CS A24PK CU A24PK and CS A28PK CU A28PK...
Страница 57: ...57 13 3 2 Soft Dry Operation Time Diagram For CS A18PK CU A18PK CS A24PK CU A24PK and CS A28PK CU A28PK...
Страница 87: ...87 Normal Deice Time Diagram Overload Deice Time Diagram...
Страница 92: ...92 a Normal Deice Time Diagram b Overload Deice Time Diagram...
Страница 98: ...98 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5...
Страница 100: ...100 Figure 9 Figure 10...
Страница 102: ...102 17 2 1 3 To remove electronic controller Figure 13 Figure 14 Figure 15 17 2 1 4 To remove discharge grille Figure 16...
Страница 104: ...104 Figure 20 Figure 21...
Страница 105: ...105 18 Technical Data 18 1 Thermostat Characteristics...
Страница 108: ...108 Heating Characteristic o Room temperature 20 C o Operation condition High fan speed o Piping length 7 5m...
Страница 112: ...112 Heating Characteristic o Room temperature 20 C o Operation condition High fan speed o Piping length 7 5m...
Страница 116: ...116 Heating Characteristic o Room temperature 20 C DBT o Operation condition High fan speed o Piping length 5 0m...
Страница 120: ...120 Heating Characteristic o Room temperature 20 C DBT o Operation condition High fan speed o Piping length 5 0m...
Страница 124: ...124 Heating Characteristic o Room temperature 20 C DBT o Operation condition High fan speed o Piping length 5 0m...