Setting the Fan Speed

• Press 

4

 to select:-

FAN

– Low Fan Speed

FAN

– Medium Fan Speed

FAN

– High Fan Speed

AUTO
FAN

– Automatic Fan Speed

The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.

Vertical Airflow Direction

Manual Operation

Press and hold the Manual Airflow Direction
Selection Button 

5

 , then release the button at

the desired airflow direction.

• Cooling / Soft Dry/

Heating 

(for Heat-Pump Model only)

The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 25 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
45 degrees downward at Heating Operation.
(for Heat-Pump Model only)

Setting the Horizontal Airflow Direction

Use this air conditioner under the following
conditions:

Cooling Model

• Adjust it manually

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

32

(30)

16

(16)

WBT

23
(-)

11
(-)

DBT

43

(24)

16

(-5)

WBT

26

(18)

11

(-6)

Indoor

Outdoor

(Unit in °C)

Heat Pump Model

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature

Minimum Temperature

DBT

32

16

WBT

23

11

DBT

43

16

WBT

26

11

Indoor

Outdoor

(Unit in °C)

Downward

Horizontal

Automatic Operation

Press the Auto Airflow Direction Button 

6

.

Cooling / Soft Dry

The louver will automatically swing up and down
to create the feeling of a refreshing breeze.

Heating 

(for Heat-Pump Model only)

When the discharge air temperature is low such
as at starts of heating operation, the air blows at
horizontal level.
As the temperature rises, the hot air blows in a
downwards direction.

OFF/ON

TE

MP

MO

DE

FAN

 SP

EE

D

AUT

O

TIM

ER

AIR

 SW

ING

RES

ET

AU

TO

CO

OL

FA

N

FA

N

SP

EE

D

DR

Y

C

H

H

O

FF

O

N

O

FF

O

N

SLE

EP

3

2

1

4

5

SELEC

T S

ET/C

AN

CEL

A

B

CONVENIENCE OPERATION

Sleep Mode Operation

To obtain a comfortable room temperature while sleeping:-
• Press 

5

.

• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.

Sleep Mode Operation Details

• When the room temperature reaches the set temperature,

the airflow volume will change to low automatically.

• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a priority.

Cooling Model

CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote
Control

• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid

to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)

1

Remove dirt using a vacuum cleaner.

2

Wash back of the air filter with water.

3

If badly soiled, wash it with soap or a mild household
detergent.

4

Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.

*

Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001088.

• Do not use benzene, thinner, scouring powder or

clothes soaked in caustic chemical to clean the
unit.

H

OFF

H

ON

H

ON

H

OFF

H

ON

H

OFF

SETTING THE TIMER

• Press the Timer Selection Button 

1

.

• Timer indicator on the indoor unit will light up.
• Select one of the following five types of operation.

Each time the button is pressed, the operation mode
is shifted in the arrow direction.

Delay OFF Timer

Example :

Operation Stops
after 1 hour
ON Timer.

Delay ON Timer

Example :

Operation starts after
6 hours.

Delay OFF and

Example :

ON Timer

Operation stops after
1 hour and re-starts
after another 5 hours.

Delay ON and

Example :

OFF Timer

Operation starts after
10 hours, and then
stops after another 8
hours.

• Then press the Timer Setting Button 

2

 or 

3

 to the

desired number of hours.
(Number of hours which can be set : 1 ~ 12)

• Press the Timer Set/Cancel Button 

4

.

Heat Pump Model

 1 hour 

Sleep shift
operation starts.

Approx. 3°C
decrease.

• Cooling or Soft Dry

Operation for sleep shift
operation will start to
avoid overcooling.

• Heating operation for

sleep shift operation will
start to avoid overheating.

Sleep
Operation
button is
pressed.

0~1 hour

Approx. 2°C
decrease.

Approx.
0.5°C
increase.

Approx. 0.5°C
increase.

Temperature

S
e

t
t
i

n
g

T
e

m

p
e

r

a

t

u

r

e

Time

 1 hour 

after approx. 8 hours of sleep shift
operation, it will stop automatically.

Time

Approx. 0.5°C
increase.

Temperature

Sleep
Operation
button is
pressed.

Sleep shift
operation
starts.

0~1 hour

 1 hour 

after approx. 8 hours of sleep shift

operation, it will stop automatically.

Approx.
0.5°C
increase.

• Cooling or Soft Dry

Operation for sleep shift
operation will start to
avoid overcooling.

S
e

t
t
i

n
g

T
e

m

p
e

r

a

t

u

r

e

37

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5