3. Detach the rear cover from the main unit by removing
the mounting screws.
4. Secure the rear cover to the wall or junction box built in
a wall with the locally procured screws, and fix the tam-
per detection lever on the wall.
Important:
• To work tamper detection properly, mount tamper
lever to the wall by screw.
• The tamper detection lever is crucial to function of
the tamper, and needs to be attached securely to
the wall for the tamper to work properly.
5. Attach the main unit to the rear cover.
(1) Hook the upper side of main unit on the rear cover.
(2) Push the lower side of main unit into the rear cover.
Important:
• Check if there is no gap between the iris reader and
rear cover.
• If the cables are lead out of the bottom side, coat
the cables with cable covers, etc.
28
■
Installation
Cautions:
• Mount the iris reader to the flat and firm wall. Besides,
secure the iris reader with the supplied mounting
screw, at the time of the mounting. Otherwise, it may
cause dropping, trouble or injury.
• Check if the wall has enough strength for mounting and
no dents. Otherwise, the tamper detection mode will be
activated.
Important:
• Do not bury this iris reader into the wall. Heat may not
be released fully, and that may cause malfunction.
• If necessary, use reinforcing screw holes.
• When the cables are lead out of the bottom side, cut off
the fixed portions before fixing the rear cover. (Refer to
p. 16.)
• Wall's capacity is 49 N {5 k
g
f} or more.
• Required pull-out capacity of a single screw/bolt is
196 N {20 k
g
f} or more.
• Before the following procedure, turn off the power sup-
ply to the iris reader.
• Refer to p. 23 for connection example.
1. Detach the front cover from the main unit by removing
the front cover fixing screw with the tamperproof screw
driver tool (supplied).
2. Detach the interface board by removing the interface
board screw. Then, remove the GND cable from the
main unit.
Front cover
Mounting screw
Rear cover
Tamper detection
lever
Reinforcing screw holes
Screws (Locally procured)
Junction box
Wall
ON
1
2
3
4
ON
1
2
3
4
Interface board
GND cable
Interface board screw