8
Pin No.
21
1
2
3
4
5
6
7
OFF
Tamper detection
cancel
Cancels the tamper
detection. Set this
switch to ON when the
front cover is removed
for servicing.
Cancel
Detect
After servicing, set
this switch to OFF.
If the front cover is
attached with this
switch ON, buzzer
sound is activat-
ed.
OFF
Ethernet Full/Half
Ethernet setting
Half
Full
Available only
when 5 is ON
OFF
Ethernet 100 M/
10 M
Ethernet setting
10 M
100 M
Available only
when 5 is ON
OFF
Ethernet auto-
negotiation
Ethernet setting
Fixed
Auto-negotia-
tion
_
OFF
IP address mode
IP address can be set
to the fixed value
regardless of the cur-
rent setting. Set this
switch to ON when the
IP address that has
been set is forgotten.
Static IP
address is
assigned.
IP address
set by an
administrator
Static IP address:
192.168.0.3
OFF
OFF
Not used
Set this switch to OFF
any time.
−
−
−
Operation
Selects the operation
mode.
Stand-alone
mode
Network
mode
−
Factory default
OFF
Start-up
Resets the software to
the factory default.
Factory
default soft-
ware
Operation
software
−
Setting name
Function
ON
OFF
Remarks
●
Setup Switches of Iris Reader
●
Setup Switches of Interface Board SW1
For access control panel
Wiegand
For card reader
RS-485
ter
mination
OFF
RS-485
ter
mination
ON
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
ON
1
2
3
4
SW1
ON
1
2
3
4
SW2
Содержание BMET200 - IRIS RECOGNITION
Страница 85: ...85 ...