40
Checking alarm information
In the event of an error with the power supply of the unit or a remote
camera included in the selected camera group, the ALARM indicator on
the unit turns on and the output of the GPI OUT connector (GPI OUT 5)
becomes On .
When an error occurs, you can check the alarm information by menu
operation .
Displaying alarm information
1 .
Press the MENU button .
2 .
Open ALARM menu [50] .
3 .
Turn the F1 dial to display the item you want to check .
The alarm status is displayed on the bottom line of the LCD panel .
1.POWER
No ALARM
<Details of each alarm>
[Select 1 . POWER]
Allows you to check the unit’s power supply alarm .
No ALARM:
When the power supply is trouble‑free .
ALARM:
When trouble has occurred with the power supply .
[Select 2 . CAM### to 11 . CAM###]
(
*
1)
Displays the alarm information for camera numbers included in the
currently selected camera group .
No ALARM:
Trouble‑free .
FAN ALM:
Trouble has occurred with the cooling fan .
P/T ALM:
Trouble has occurred with the pan/tilt operation .
FAN ALM+P/T ALM:
Trouble has occurred with the cooling fan and pan/tilt
operation .
(*1) CAM### is used to indicate a camera number included in the
selected camera group . For example, when the F1 dial is turned
while camera group “10” is selected, “2 . CAM91” to “11 . CAM100”
are displayed on the top line of the LCD panel .
z
z
When an alarm has occurred, stop operation immediately and be
sure to contact your dealer .
Continued use may cause the unit or a remote camera to
malfunction .
Note