Registering preset memory (STORE)
1 .
Press one of the camera selection buttons
[CAMERA SELECT/GROUP SELECT] to select the
remote camera to be operated .
2 .
Output the images to be shot to the monitor .
3 .
Press the PMEM button to turn on its indicator .
4 .
Press the MEM STORE button to turn on its indicator .
5 .
Operate the PAN/TILT lever and ZOOM button to
determine the camera angle to register .
If necessary, adjust the focus and iris as well .
6 .
Hold down a number button to specify the preset
number to register .
“STORE COMPLETE” appears on the second line of the LCD panel .
The current camera positions and settings are registered to the
preset memory of the remote camera .
z
To continue registering different camera angles to a preset
memory belonging to the same “page number”, repeat steps
5
to
6
.
z
z
When registering preset memory, hold down the number
button .
z
z
If a number button that already has preset memory registered
is held down, the saved data will be deleted as it will be
overwritten .
However, if a number button that already has tracing memory
registered is held down, “Used by TMEM .” will be displayed on
the LCD panel and the corresponding preset memory data will
not be overwritten .
Notes
Recalling preset memory (RECALL)
1 .
Press one of the camera selection buttons
[CAMERA SELECT/GROUP SELECT] to select the
remote camera to be operated .
2 .
Press the PMEM button to turn on its indicator .
3 .
Hold down a number button to specify the preset
number to recall .
The registered settings are recalled .
z
When the indicator of the MEM STORE button or MEM DELETE
button is on, preset memory is not recalled when a number button
is pressed .
Press the PMEM button or press the MEM STORE button or
MEM DELETE button with the indicator turned on to turn off its
indicator, and then perform the operation .
Deleting preset memory (DELETE)
1 .
Press one of the camera selection buttons
[CAMERA SELECT/GROUP SELECT] to select the
remote camera to be operated .
2 .
Press the PMEM button to turn on its indicator .
3 .
Press the MEM DELETE button to turn on its indicator .
4 .
Hold down a number button to specify the preset
number to delete .
“DELETE COMPLETE” appears on the second line of the LCD panel
and the registered settings are deleted .
z
z
When deleting preset memory, hold down the number button .
z
z
When the preset number used with tracing memory is held
down, “Used by TMEM .” will be displayed on the LCD panel
and the corresponding preset memory data will not be deleted .
⇒
For details on tracing memory, refer to “Deleting tracing
memory (DELETE)” (page 20) .
z
z
If the above operation is performed when controlling
AW‑PH400 (connected via AW‑IF400), “DELETE COMPLETE”
is displayed on the LCD panel but deletion of the preset
memory is not be executed and the registered settings are
retained .
Notes
Operating preset memory (PMEM)