-42-
#6
Black Level Setting [Pedestal: –30 - +30]
The black level (pedestal) of the luminance (Y) sig-
nal can be set. Used in adjusting the black levels
of two or more cameras.
#7
Chroma Level Adjustment
[Chroma Level: –3 - +3]
Chroma Level can be decreased or increased to
three levels.
#8
White Balance Setting [White Bal: ATW/AWC A/
AWC B/P SET 3 200K/P SET 5 600K]
ATW:
The white balance is automatically adjusted
to the optimum position.
AWC A, AWC B:
Color temperature conditions at
two points can be stored at AWC A and AWC B.
Once the white balance is adjusted with the
Item/AWC switch on the back of the camera, it
is no longer necessary to set the white balance
again if you simply select AWC A or AWC B,
provided that the camera is used under the
same conditions.
Fine color adjustment can be made after setting
AWC by red/blue gain adjustment in Painting
Setting
$0
or from the RCU (RCB).
P SET 3 200K:
The white balance is adjusted to
3 200K illumination.
P SET 5 600K:
The white balance is adjusted to
5 600K illumination.
Note
Neither P SET 3 200K nor P SET 5 600K can be set
from the RCU (RCB) or the hybrid control panel.
#9
Highlight Chroma Setting [Highlight Chroma:
OFF/LOW/HIGH]
At LOW or HIGH, the color dynamic range widens to
prevent highlighted white portions from suppres-
sion.
$0
Painting Setting [Painting: R Gain, B Gain,
R Pedestal, B Pedestal: –30 - +30]
R Gain, B Gain:
Fine adjustment of the white balance can be
made after AWC setting when AWC A or AWC B
is selected in White Balance Setting
#8
. In case
of using the RCU (RCB), use the R/B gain con-
trols for this purpose. The set value returns to
±0 after AWC setting in using the camera alone.
R Pedestal, B Pedestal:
Fine adjustment of the black balance can be
made after ABC setting.
In case of using the RCU (RCB), use the R/B
pedestal controls for this purpose. The set
value returns to ±0 after ABC setting in using the
camera alone.