-26-
●
COLOR PHASE ADJUSTMENT
Supply the output signal (split color bar) from the color
special effect generator to a color monitor or vec-
torscope. Adjust the color phase of the camera.
[ADJUSTMENT with RCU (RCB, Hybrid control panel)]
Use the subcarrier phase coarse adjustment control
and subcarrier phase fine control.
* It is recommended that a vectorscope be used for
maximum accuracy in color phase adjustment.
[ADJUSTMENT by CAMERA]
1. Press the NO/BAR switch for over 5 seconds for the
color bar mode.
2. Select [G/L. Color Bar Set] on the main menu, then
select [SC Coarse] on the sub menu.
3. Make coarse adjustment with the YES/ABC switch
and the NO/BAR switch.
Magenta
Green
Cyan
Yellow
White
Red
Blue
Black
Magenta
Green
Cyan
Yellow
White
Red
Blue
Color bar of
camera
Color bar of special
effects generator
**G/L.
Color Bar Set**
H Phase
±
0
SC Coarse 1
SC Fine
±
0
Color Bar Set 7.5IRE
Return
Sprit line
CAUTION:
When horizontal phase adjustment is required using
RCU (RCB) or Hybrid Control Panel, BAR/CAM switch
should be set to BAR. Horizontal phase cannot be
adjusted if the switch is in the CAM position. After
adjustment set BAR/CAM switch back to CAM.
CAUTION:
When color phase adjustment is required using RCU
(RCB) or Hybrid Control Panel, BAR/CAM switch should
be set to BAR. Color phase cannot be adjusted if the
switch is in the CAM position. After adjustment set
BAR/CAM switch back to CAM.
4. Select [SC Fine] on the sub menu. Perform fine
adjustment with the YES/ABC switch and the
NO/BAR switch.
Содержание AWE300S - SEPERATE CAMERA