-39-
#0
Auto Iris Level Fine Adjustment [Auto Iris Adust:
ON/OFF]
ON:
Fine adjustment of auto iris convergence
level can be made with the iris control when
the iris switch on the RCU (RCB) or on the
hybrid control panel is in the AUTO posi-
tion.
OFF:
The iris control is invalid when the iris
switch on the RCU (RCB) or on the hybrid
control panel is in the AUTO position.
ALL
CENTER
TOP CUT
BOTTOM CUT R/L CUT
R
B
R
B
PED
TOTAL
PED
A
B
ATW
AWC
AUTO
HOLD
ABC
IRIS
MAN
AUTO
1000
S/S
ELC
500
100
OFF
SHUTTER
SCENE
2
1
3
USER
SET
AUTO/ATW
PAINTING
GAIN
RCU (RCB)
Iris Control
Iris Switch
■
Setting and Changing of the
Setting Items (User Mode)
@7
Video Level Adjustment [Picture Level:
–50 - +50]
Convergence level of AUTO IRIS/AGC/ELC can be
adjusted.
@8
Detecting Ratio Adjustment [Light PEAK/AVG:
P50 - A50]
The ratio of AUTO IRIS/AGC/ELC detected peak to
average can be adjusted within a range.
@9
Photometric Measurement Method Setting
[Light Area: ALL, CENTER, TOP CUT, BOTTOM
CUT, R/L CUT
A photometric measurement method can be select-
ed for AUTO IRIS/AGC/ELC.
ALL:
All the screen area is measured.
CENTER:
The screen is measured mainly in the
center area, about one-third of both the top and
bottom and one-third of both the right and left
portions of the screen are excluded from mea-
surement.
TOP CUT:
About one-third of the top portion of the
screen is excluded from measurement.
BOTTOM CUT:
About one-third of the bottom por-
tion of the screen is excluded from measure-
ment.
R/L CUT:
About one-third of both the right and left
portions of the screen are excluded from mea-
surement.