IPv4 network
DHCP [On, Off]
Select the method in which the IP address is configured.
Factory settings:
Off
<NOTE>
• When [DHCP] is set to [On], AW-RP150/AW-RP60’s automatic
configuration of IP address (AUTO IP) cannot be used.
IP address(IPv4)
Input the unit’s IP address here when the DHCP function is not
going to be used. Input an address that will not duplicate an existing
IP address which has been set for a personal computer or another
network camera.
Factory settings:
192.168.0.10
<NOTE>
• Multiple IP addresses cannot be used even when the DHCP
function is used. For details on the DHCP server settings, consult
your network administrator.
Subnet mask
Input the unit’s subnet mask here if the DHCP function is not going to
be used.
Factory settings:
255.255.255.0
Default gateway
Input the unit’s default gateway if the DHCP function is not going to
be used.
Factory settings:
192.168.0.1
<NOTE>
• Multiple IP addresses cannot be used for the default gateway even
when the DHCP function is used.
For details on the DHCP server settings, consult your network
administrator.
z
IPv6 network
Manual [On, Off]
Enable or disable manual configuration of the IPv6 address.
On
Enter the IPv6 address manually.
Off
Disable manual entry of the IPv6 address.
Factory settings:
Off
IP address(IPv6)
When [Manual] is set to [On], the IPv6 address must be entered
manually.
Be sure to enter an address unique from other devices.
<NOTE>
• When connecting to the manually specified IP address through a
router, use an IPv6-compatible router, and enable the automatic
configuration function for the IPv6 address. Be sure to configure
an IPv6 address that includes the prefix information provided
by the IPv6-compatible router. For details, refer to the operating
instructions for the router.
• Link local address cannot be set.
Default gateway
When [Manual] is set to [On] for [IPv6 network], enter the default
gateway for the unit’s IPv6 network.
Factory settings:
blank
<NOTE>
• It is not possible to set the default gateway when [DHCPv6] is [On].
DHCPv6 [On, Off]
Enable or disable use of the IPv6 DHCP function.
Configure the DHCP server so that the same IP address is not
configured for a personal computer that does not use the DHCP
function and other network cameras. For details on server settings,
consult your network administrator.
On
Use the IPv6 DHCP function.
Off
Do not use the IPv6 DHCP function.
Factory settings:
Off
DNS [Auto, Manual]
Set whether the DNS server address is to be acquired automatically
(Auto) or to be manually input (Manual).
The DNS setting needs to be performed if [Manual] is set.
When using the DHCP function, if you set to [Auto], then the DNS server
address will be acquired automatically.
Consult the system administrator regarding the settings.
Factory settings:
Manual
Primary server address
Secondary server address
Enter the IPv4/IPv6 address of the DNS server.
For details on the IPv4/IPv6 address of the DNS server, consult your
system administrator.
126