22
Installation Instructions
Connections
(continued)
■
System example 2 (connection with commercially available controller,
RS-422 connection)
RS-422 communication connector
Commercially
available controller
AW-HE42
Supplied AC adaptor
●
Configure the service switches at the bottom of the unit.
For details on the service switches, see “Service switch settings” (page 64).
SW1
Camera address
setting (standard
serial communication)
Set to AUTO or 1 to 7.
(Set address numbers so that they do not duplicate each other.)
SW2
SW3
SW4
Communication
format
Enable standard serial communication (ON).
SW7
Communication baud
rate
Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially
available controller.
SW8
Communication
connector
Set to RS-422 (OFF).
●
Configure the following items in the camera menu.
1.
Display [System] menu
[Protocol]
[Model Select].
2.
Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type.
●
Daisy-chain connections are not possible for RS-422 connections.
Note