- 24 (E) -
ENGLISH
$
Total pedestal level adjustment
(Use an oscilloscope or a waveform monitor for this
adjustment.)
This step is to adjust the black levels (pedestal levels) of two
or more cameras to be the same.
[ADJUSTMENT by CAMERA]
1. Close the lens.
2. Select Pedestal item in the brightness setting Sub Menu.
(Select [Pedestal] in the [Iris, Shutter, Gain Set] sub
menu in User Mode.)
3. Set the pedestal level to 0.025 V with the YES/ABC
switch or the NO/BAR switch.
[ADJUSTMENT with RCU (RCB, hybrid control panel)]
Adjust the pedestal level to 0.025 V with the total pedestal
adjustment.
NO/BAR switch
YES/ABC switch
TOTAL PEDESTAL