DANGER
• Make sure that power is turned OFF before starting wiring. Failure to do so may result in an
electric shock or fire.
• Always connect ground wire. Failure to do so may result in an electric shock or fire.
• Wiring work should always be carried out by qualified electrician. Failure to do so may result
in an electric shock or fire.
• Always install the unit before wiring. Failure to do so may result in an electric shock or
personnel injury.
• Always close terminal cover before turning ON the inlet power and do not open terminal
cover during power ON.
Failure to do so may result in an electric shock or fire.
• Do not operate switches or knobs with wet hands. Failure to do so may result in an electric
shock.
• Do not touch inverter terminals during Power ON even in stopping status. Failure to do so
may result in an electric shock.
• The STOP button is not designed for emergency stop purpose, so set a separate button for
emergency stop. Failure to do so may result in personnel injury.
• Depending on the start mode and settings of ride-through function, if operating signal is ON
or the power is restored from a power failure, the inverter may start (or restart) suddenly.
Keep away from the unit to avoid injury.
〔
Design the machine so that it can ensure personal safety even if the inverter starts
suddenly.
〕
• Depending on the setting of start mode function, when reset fault trip with the operating
signal present,the inverter may restart suddenly.
(Always take measures to ensure personal safety.) Failure to do so may result in personnel
injury.
• When retry function is in use, the inverter may automatically start (restart) suddenly, so do
not approach it. (Always take measures to ensure personal safety.) Failure to do so may
result in personnel injury.
• While auto-tuning function is in use, the inverter will automatically drive the motor in the
stand-along mode when the RUN button on the panel is pressed.
(Always take measures to ensure personal safety.) Failure to do so may result in personnel
injury.
• Always confirm and adjust parameters before operation.An unexpected operation may occur
on some parts.
(Always take measures to ensure personal safety.) Failure to do so may result in personnel
injury.
• If data is changed during operation, the motor and motor load may suddenly start/stop for the
great fluctuation.
(Always take measures to ensure personal safety.) Failure to do so may result in personnel
injury.
• Wait at least 5 minutes after turning OFF the power before starting maintenance and
inspection. Failure to do so may result in an electric shock.
• Maintenance, inspection and part replacement work must be done only by qualified persons.
(Remove metal articles such as watch, bracelet(s) etc. before operation.)
(Use tools treated with insulation.) Failure to do so may result in an electric shock or
personnel injury.
• Do not replace cooling fan during power ON. Failure to do so may result in an electric shock.
• Do not make modifications to the inverter. Failure to do so may result in personnel injury.