![Panasonic AK-UCU600P Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/panasonic/ak-ucu600p/ak-ucu600p_operating-instructions-manual_3533106074.webp)
CCU menu
-
74
-
INTERCOM2
This is the selection screen for the INTERCOM2 menu.
INTERCOM2
4W/RTS/CLRCOM
4W
4W INPUT GAIN
0dB
4W INPUT LEVEL
0dB
4W OUTPUT LEVEL
0dB
RTS INPUT LEVEL
0dB
RTS OUTPUT LEVEL
0dB
RTS CANCEL LEVEL
0.0dB
CLRCOM INPUT LEVEL
0dB
CLRCOM OUTPUT LEVEL
0dB
CLRCOM CANCEL LEVEL
0.0dB
RST/CLRCOM LOAD
OFF
___ indicates factory default settings.
Item
Setting value
Setting details
4W/RTS/CLRCOM
4W
RTS
CLRCOM
Select the intercom 2 voice I/O method.
4W INPUT GAIN
0dB
20dB
Switch the 4W (intercom 2) input gain.
4W INPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Switch the 4W (intercom 2) input level.
4W OUTPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Switch the 4W (intercom 2) output level.
RTS INPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Switch the RTS (intercom 2) input level.
RTS OUTPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Switch the RTS (intercom 2) output level.
RTS CANCEL LEVEL
-20.0dB to +20.0dB *
1
(0.5dB Step)
Switch the RTS (intercom 2) I/O cancellation level.
CLRCOM INPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Set the clear-com (intercom 2) input volume.
CLRCOM OUTPUT LEVEL
-40dB to 0dB to +20dB
(1dB Step)
Set the clear-com (intercom 2) output volume.
CLRCOM CANCEL LEVEL
-20.0dB to +20.0dB *
1
(0.5dB Step)
Adjust the clear-com (intercom 2) I/O cancellation signal level.
RTS/CLRCOM LOAD
ON
OFF
Switch ON or OFF for the intercom 2 RTS/CLRCOM 200 Ω load.
*1: The default setting varies depending on adjustment at the factory.