![Panasonic AK-UCU600P Скачать руководство пользователя страница 127](http://html1.mh-extra.com/html/panasonic/ak-ucu600p/ak-ucu600p_operating-instructions-manual_3533106127.webp)
Reference
- 127 -
Example of tally input connections
12.4 kΩ
*
1
2.2 kΩ
5 V
AK-UCU600
R TALLY IN (H)
G TALLY IN (H)
YL TALLY IN (H)
R TALLY IN (C)
G TALLY IN (C)
YL TALLY IN (C)
12.4 kΩ
*
1
3.9 kΩ
5 V
AK-UCU600
R TALLY IN (H)
G TALLY IN (H)
YL TALLY IN (H)
R TALLY IN (C)
G TALLY IN (C)
YL TALLY IN (C)
*1: Equivalent circuit
[ROP] connector (page 26: 5)
HR10G-10R-10SC (71) (Hirose Electric Co., Ltd.)
Pin No.
Function
Flow of signal
1
ROP CONT (H)
CCU→ROP
2
ROP CONT (C)
CCU→ROP
3
ROP DATA (H)
ROP→CCU
4
ROP DATA (C)
ROP→CCU
5
NC
6
NC
7
NC
8
NC
9
+16 V OUT
CCU→ROP
10
GND
●
Connector of cable
HR10A-10P-10P (73)
1
2
3
4
5
6
7
8
10
9