6
Before installing
Before installing
Drop prevention measure
Take the drop prevention measure by attaching the drop prevention wire to the mounting screw hole.
Mounting the camera to the pan/tilt head
Prepare a commercially available drop prevention wire when mounting this unit to the pan/tilt head.
Mounting the camera to anything other than the pan/tilt head
Prepare the drop prevention wire and camera mounting fixture when attaching to anything other than the
pan/tilt head.
1 Drop prevention wire (optional): 2
Always use the drop prevention wire.
A drop prevention wire is available as an optional accessory. Use with as small slack as allowed by the
installation location or the installation method.
Secure wire diameter of 2 mm (3/32 inches) or more, length of 300 mm (11-13/16 inches) or less,
and strength of the mounting section of 2000 N or more when using a commercially available drop
prevention wire. Also, separately prepare the mounting screw matching the mounting specification.
6.4 mm (1/4 inches)
4.5 mm (3/16 inches)
6.4 mm (1/4 inches)
4.5 mm (3/16 inches)
2 mm (3/32 inches)
Length of the wire (300 mm) (11-13/16 inches)
Installation side
Camera side
11 mm (7/16 inches)
f
Wire length 300 mm (11-13/16 inches): Parts number (DVDW1001ZA)
2 Camera mounting screws (to be obtained by customer): 2
Size: 3/8-16 UNC
Camera mounting fixture
6 to 8 mm (1/4 to 5/16 inches)
Consider the thickness of the camera mounting fixture for the length.
3 Installation side wire mounting screw (M6 or M4) (to be obtained by customer): 2
Use an anchor bolt at the installation location and secure the strength of ten times of the entire weight.
4 Flat washers (to be obtained by customer): 4 (for mounting the camera)
For 3/8 inch screw
5 Spring washers (to be obtained by customer): 4 (for mounting the camera)
For 3/8 inch screw
6 Camera mounting fixture (to be obtained by customer): 1
Prepare the fixture with material and shape that can withstand the entire weight of the camera and the
lens.