Installation
7
Installation
Securely fix to the camera housing, the pan/tilt head, or the tripod using the mounting screw holes at the top and bottom.
Always use tools when installing and confirm that there is no danger of drop.
@
@
NOTE
t
Hold the main unit with both hands by the left and right fittings when attaching it to a tripod or when carrying it.
Upper side
Mounting screw holes
(3/8-16 UNC)
Drop prevention wire
mounting screw hole (M4)
Bottom side
@
@
NOTE
t
Always use an anchor bolt when installing the mounting fixture into the ceiling or the wall.
Secure drawing strength of ten times or larger against the entire weight including the mounting fixture, camera, lens, and cables.
t
Always take the drop prevention measure using the screws on the tripod when mounted on a tripod.
t
The weight including the camera body, lens, and cables should be 6 k
]
(13.20 lbs) or less.
t
Attach the drop prevention wire so the distance of drop will be 300 mm (11-13/16 inches) or less.
t
Tighten the mounting screws with the following torques, and confirm that there is no rattling.
- 3/8 inch screw: 12 N·m (120 k
]
f·cm)
- M4 screw: 1.0 N·m (10 k
]
f·cm)
t
Do not use impact driver. Doing so may damage the screws.
t
The set feet may be taken off the main unit to suit the usage situation.
t
Securely install the safety wire, etc., separately following the operating instructions of the manufacturer
when installing the commercially available mounting fixture.
t
Do not reuse the wire that was used (dropped) once. Always use a new wire when reinstalling.
t
Take caution to install so the rating plate is visible.
Set feet
Mounting screw holes
(3/8-16 UNC)
Drop prevention wire
mounting screw hole (M4)