51
704
EMPHASIS
0000
0001
OFF
ON
For setting the emphasis ON or OFF.
705
MONI SEL
0000
0001
PLYPCM
PLYCUE
730
DOUBLE REC
0000
0001
OFF
ON
732
LIMITER CH1
0000
0001
OFF
ON
For setting the CH1 audio limiter operation.
0: The limiter does not operate.
1: The limiter operates.
733
LIMITER CH2
0000
0001
OFF
ON
For setting the CH2 audio limiter operation.
0: The limiter does not operate.
1: The limiter operates.
734
LIMITER CH3
0000
0001
OFF
ON
For setting the CH3 audio limiter operation.
0: The limiter does not operate.
1: The limiter operates.
735
LIMITER CH4
0000
0001
OFF
ON
For setting the CH4 audio limiter operation.
0: The limiter does not operate.
1: The limiter operates.
736
MIC LOWCUT
CH1
0000
0001
OFF
ON
For setting the high-pass filter of the CH1 microphone ON or OFF.
737
MIC LOWCUT
CH2
0000
0001
OFF
ON
For setting the high-pass filter of the CH2 microphone ON or OFF.
738
MIC LOWCUT
CH3
0000
0001
OFF
ON
For setting the high-pass filter of the CH3 microphone ON or OFF.
739
MIC LOWCUT
CH4
0000
0001
OFF
ON
For setting the high-pass filter of the CH4 microphone ON or OFF.
706
REC CUE
0000
0001
0002
CH1
CH2
CH1+2
For setting the audio input signals which are to be recorded on the cue
track.
0: CH1 input signals are recorded.
1: CH2 input signals are recorded.
2: CH1 and CH2 input signals are mixed and recorded.
731
MONI OUT
0000
0001
0002
0003
0004
0005
CH1
CH2
CH3
CH4
CH1+2
CH3+4
AUDIO menu
Item
Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
The underlining indicates the factory setting.
Setup Menus
For setting whether the CH1 and CH2 input signals are to be recorded
simultaneously on CH3 and CH4.
(This item is valid only in the 50 Mbps mode.)
0: The signals are not recorded simultaneously.
(The CH3 and CH4 inputs signals are recorded on CH3 and CH4.)
1: The signals are recorded simultaneously.
For setting the audio signals which are to be output from the AUDIO OUT
connectors (PHONO), HEADPHONE jack and EARPHONE jack during
PLAY (FWD
a
1).
0: PCM audio signals are output.
1: Cue audio signals are output.
For setting the audio signals to be monitored at the AUDIO OUT connectors
(PHONO) when PLYPCM has been selected as the No. 705 setting.
The cue audio signals are always output when PLYCUE has been selected
as the No. 705 setting.
0: The audio signals of CH1 are monitored.
1: The audio signals of CH2 are monitored.
2: The audio signals of CH3 are monitored.
3: The audio signals of CH4 are monitored.
4: The audio signals of CH1 and CH2 are mixed and monitored.
5: The audio signals of CH3 and CH4 are mixed and monitored.