11
Chapter
Men
uOper
ations
Item
Setting
Notes
TYPE A NEAR
Sets the near end voltage for TYPE A. (Adjustable in
0.1 V units.)
11.0 V ... 13.7 V ... 15.0 V
TYPE A END
Sets the end voltage for TYPE A. (Adjustable in 0.1 V
units.)
11.0 V ... 13.3 V ... 15.0 V
TYPE B FULL
Sets the full voltage for TYPE B. (Adjustable in 0.1 V
units.)
12.0 V ... 16.0 V ... 17.0 V
TYPE B NEAR
Sets the near end voltage for TYPE B. (Adjustable in
0.1 V units.)
11.0 V ... 13.1 V ... 15.0 V
TYPE B END
Sets the end voltage for TYPE B. (Adjustable in 0.1 V
units.)
11.0 V ... 12.8 V ... 15.0 V
NEAR END CANCEL
Sets to cancel battery near end warning. ON, OFF.
ON, OFF
• When set to ON, pressing the DISP/MODE CHK
button stops the flashing of warning and tally lamps.
CARD FUNCTIONS screen
Item
Setting
Notes
SCENE FILE
Reads/writes scene files from/onto the SD memory
card.
FILE SELECT:
Selects scene files (1 to 4).
READ:
Reads the selected scene file (1 – 4) settings
stored on the SD memory card.
WRITE:
Saves the current scene file (1 – 4) settings to
the SD memory card.
TITLE RELOAD:
Reloads title list.
USER FILE
Reads/writes user files (files other than SCENE FILES)
from/onto the SD memory card.
FILE SELECT:
Selects user files (1 to 4).
READ:
Reads the user file (1 – 4) settings stored on
the SD memory card.
WRITE:
Saves the current user file (1 – 4) settings to
the SD memory card.
TITLE RELOAD:
Reloads title list.
SD CARD FORMAT
Formats SD memory cards.
• Setting data file operations may end in error during playback or when the menu option PC MODE is set to ON in the
SYSTEM SETUP screen. Set the menu option PC MODE to OFF before making file operations.
____ indicates the factory setting