INF-37
7-2-2. Write data of SYS EEPROM
1. This camera recorder is set to
CAM
mode.
2. Select
“SYSCON(S)”
section after start up the PC EVR software, and click
“OK”
button.
3. Select
“Open Image File(O)”
in
“File(F)”
menu, the screen for selecting the file to be written will appear.
4. Select the file to be written in the Camera-Recorder.
5. Click
“Open(O)”
button in the
Open
screen and reading starts.
6. Select
“EEPROM Write(W)”
in
“File(F)”
menu, following message will appear.
When
“Cancel(C)”
button is clicked, writing EEPROM data is canceled.
When
“OK”
button is clicked, the writing starts.
7. Red is displayed to the status lamp while writing it. When writing is completed, the status lamp changes into a
blue display.
NOTE:
Hour meter value (OPERATION TIME) of camera recorder is saved in SYS EEPROM.
After EEPROM backup data of SYSCON is written back to the replaced P.C.Board, please turn the power
supply OFF and ON with the following procedure.
-> Write back SYS EEPROM data
-> Remove the DC cable.
-> Return the power SW of camera recorder to the off position.
-> Connect the DC cable.
-> Turn the power SW of camera recorder to ON.
-> Turn the power SW of camera recorder to OFF.
-> After turning the power SW of camera recorder to ON, confirm that Hour Meter value is returned to the
original value.