1.7.4.2
Wiring the RS485 Interface
Use the optional RS485 serial port to network multiple XMT868i flow transmitters to a single computer terminal. As an
option, the standard RS232 port on the XMT868i may be configured as a two-wire, half-duplex RS485 interface.
IMPORTANT:
The XMT868i must be configured at the factory for RS485 operation. The maximum cable length for
RS485 is 4000 ft (1200 m).
To wire the RS485 serial port, refer to Figure 10 on page 23 and complete the following steps:
1.
Disconnect the main power to the unit and remove the rear cover.
2.
Install the required cable clamp in the chosen conduit hole on the side of the electronics enclosure.
3.
Feed one end of the cable through the conduit hole, wire it to terminal block
J1
and secure the cable clamp. Use
the information in Table 2 to wire a suitable cable for connecting the XMT868i to the external device.
WARNING!
To meet CE Mark requirements, all cables must be installed as described in
Appendix A,
CE Mark Compliance
.
4.
If wiring of the unit has been completed, reinstall the rear cover on the enclosure and tighten the set screw.
Proceed to the next section to continue the initial wiring of the unit.
Table 2: RS485 Connections
J1 Pin #
Signal Description
9
Data +
8
Data -
7
Shield
6
Not Used
5
Not Used
4
Not Used
Содержание DigitalFlow XMT868i
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 28: ...Chapter 1 Installation 20 DigitalFlow XMT868i Startup Guide...
Страница 34: ...Chapter 1 Installation DigitalFlow XMT868i Startup Guide 26...
Страница 52: ...Chapter 2 Initial Setup 18 DigitalFlow XMT868i Startup Guide...
Страница 76: ...Appendix A CE Mark Compliance 10 DigitalFlow XMT868i Startup Guide...
Страница 86: ...Chapter 20 DigitalFlow XMT868i Startup Guide no content intended for this page...
Страница 90: ...2 DigitalFlow XMT868i Startup Guide...
Страница 92: ...2 Doc Tittle Manual Type...
Страница 93: ......