2. Event:
When this option is
selected, the log will display a list
of events such as power failure,
program start, and program end.
3. Closed Application
Information:
When this option
is selected, the log will display the
names and location of any files that
were auto-saved by the software.
1. Log Display:
This window displays
the information as
selected by the Event,
Closed Application
Information, or Data
Record option buttons.
6. Cancel:
Closes
the window without
saving any changes.
7. Clear:
Clears the
selected log.
5. OK:
Closes the
window and saves
any changes.
4. Data Record:
When this
option is selected, the log will dis-
play a record of the items that are
shown in the main window.
10
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901
Home Cinema Power Control Software Instructions
(continued)
Battery Features
LOG MENU
Testing The Battery Backup Function
Once you have set up your UPS system, you may wish to test it. Make
sure that the UPS has been charged for at least 4 hours before testing.
To test the UPS, simply depress the test button located on the front of
the unit. The unit will cycle to battery and emit an audible beep. The unit
will stop beeping when the test is complete.
You may also use the self-test function in the software. To use the soft-
ware self-test, open the main window, and then click mode on Setup.
Click the red run button. The unit will cycle
to battery mode and emit an audible beep. With the software
self-test, the unit will switch back to AC power automatically.
Battery Replacement
Read and follow the
IMPORTANT SAFETY INSTRUCTIONS
before servicing
the battery.
M1500-UPS-PFP Battery Replacement Policy
Batteries are included under the M1500-UPS-PFP 3 year warranty.
PF Power will replace M1500-UPS-PFP batteries if the fail within the 3
year product warranty period. For battery replacement information and
instructions please contact Panamax Customer Service at www.pana-
max.com or call 800-472-5555.
If batteries fail after the M1500-UPS-PFP 3 year product warranty then
the customer is responsible for battery replacement. For detailed battery
replacement information and instructions please contact Panamax
Customer Service at www.panamax.com. or call 800-472-5555.
Service the battery under the supervision of personnel knowledgable
of batteries and their precautions.
Sevicing the battery should only be
performed by qualified personnel.
CAUTION!
USE ONLY THE SPECIFIED TYPE OF BATTERY.
Contact Panamax Customer Service at www.panamax.com
or call 800-472-5555 for battery replacement information.
CAUTION!
The battery may present the risk of electrical shock.
Do not dispose of batteries in a fire as they may explode. Follow all
local ordinances regarding proper disposal of batteries.
CAUTION!
Do not open or mutilate the batteries. Released electrolyte is
harmful to the skin and eyes and may be toxic
CAUTION!
A battery can present a high risk of short circuit current and
electrical shock. Take the following precautions before replacing the bat-
tery:
1.
Remove all watches, rings or other metal objects.
2.
Only use tools with insulated handles.
3.
Do not lay tools or metal parts on top of battery or any terminals.
4.
Wear rubber gloves and boots.
5.
Determine if the battery is inadvertently grounded. If inadvertently
grounded, remove source of ground.
CONTACT WITH A GROUNDED
BATTERY CAN RESULT IN ELECTRICAL SHOCK!
The likelihood of such
shock will be reduced if such grounds are removed during installation
and maintenance (applicable to a UPS and a remote battery supply not
having a grounded circuit).