Home Cinema Power Control Software Instructions

Overview

Panamax’s Home Cinema Power Control software is designed for
use with Windows 95, Windows 98, Windows Me, Windows NT,
Windows 2000 and Windows XP.  It works in conjunction with
the UPS to provide full protection of home theater equipment
including digital video recorders, home theater PC’s (HTPC) 
and video projectors/lamps.  

This program may be used temporarily during the Initial system
setup.  An installer can use a notebook computer to set the vari-
ables within the Home Cinema Power Control software.  Once the
setup is completed, the notebook computer can be disconnected.
All settings are stored in the UPS.

The software can also be used to manage a Home Theater
Personal Computer (HTPC).  Functionality is very similar to a
standard UPS with a PC.  The UPS can provide continued power
to the HTPC to maintain recording capabilities if it is being used 

as a digital video recorder.  It is also capable of saving open doc-
uments and shutting down the HTPC during extended power fail-
ures.  This requires a permanent RS232 connection to the HTPC
and having the Home Cinema Power Control software running in
the background on the HTPC.  When a power failure occurs,
open files are saved under auto-assigned file names or existing
file names and the files closed.  The computer and UPS are 
automatically shutdown to conserve battery power.  Files with
auto-assigned names will be saved under C:\PCTemp, where C 
is the name of your main hard drive.  Files that have previously
been saved will be saved in their original location.

There is also a Schedule feature that can automatically save and
close open files and then shutdown the computer and UPS at a
user specified date and time as well as re-start the computer at 
a user specified date and time.  Use of this feature is optional
and is not required for the power failure shutdown to occur.

2. Power Button:

Closes the program window.

3. Minimize Button:

Minimize the program window.

4. Setup Button:

Opens the Setup Window.

1. Log Button: 

Opens the Event Log Window.

6. Schedule Button:

Click this button to access the
Schedule Window.

5. Model:

Shows the model

of UPS that is being used.

7. Status Bar:

Displays messages

about the status of the software.

MAIN MENU

Содержание M1500-UPS

Страница 1: ...ual POWER TEST MAX Home Cinema UPS Pure Sine Wave Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1690 Corporate Circle Petaluma CA...

Страница 2: ...tions pgs 7 8 9 10 Battery Features pgs 10 11 Diagnostics pg 11 Troubleshooting pg 12 Technical Specifications pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties...

Страница 3: ...ife support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the ris...

Страница 4: ...nd does not service equipment with large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be rated for 15 Amps 5 Press the power switch to t...

Страница 5: ...nd the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator...

Страница 6: ...th outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is output 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will...

Страница 7: ...me Cinema Power Control Software The M1500 UPS has one rear panel serial port that provides the ability to program special functions safely shutdown a home the ater PC HTPC or integrate the UPS with h...

Страница 8: ...and 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control...

Страница 9: ...own the HTPC during extended power fail ures This requires a permanent RS232 connection to the HTPC and having the Home Cinema Power Control software running in the background on the HTPC When a power...

Страница 10: ...ds to be used exclusively for the UPS software 12 Time between power failure and shutdown For use with an HTPC This is the user controllable delay between when the power fails and the software starts...

Страница 11: ...tes and times of any scheduled startups and shut downs 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is...

Страница 12: ...the red run button The unit will cycle to battery mode and emit an audible beep With the software self test the unit will switch back to AC power automatically Battery Replacement Read and follow the...

Страница 13: ...eps Rapid Beeps Long Beep Long Beep None Off None Condition Normal AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input v...

Страница 14: ..._____________________________Yes Maintenance free____________________________________________________________Yes Lead acid___________________________________________________________________Yes User re...

Страница 15: ...outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY M...

Страница 16: ...pace 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP...

Страница 17: ...is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to U...

Страница 18: ...n AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high...

Страница 19: ...e date of purchase that the unit shall be free of defects in design materi al or workmanship and Panamax will repair or replace any defective unit Upgrade Policy Valid only in the United states and Ca...

Страница 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 Email sales panamax com Web www panamax com 2005 Panamax INS0763 REV B 7 05...

Отзывы: