background image

FCC Notice

This equipment has been tested and found to
comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reason-
able protection against harmful interference in
residential installation.  This equipment gener-
ates, uses, and can radiate radio frequency
energy and, if not installed and used in accor-
dance with the instructions, may cause harm-
ful interference to radio communications.
However, there is no guarantee that interfer-
ence will not occur in a particular installation.
If this equipment does cause harmful interfer-
ence to radio or television reception, which
can be determined by turning the equipment
off and on, the user is encouraged to try to
correct the interference by one or more of the
following measures: 

(1)

Reorient or relocate the receiving antenna.

(2)

Increase the separation between the equip-

ment and receiver.

(3)

Connect the equipment into an outlet on a

circuit different from that to which the receiver
is connected. 

(4)

Consult the dealer or an experienced

radio/TV technician for help. Any special
accessories needed for compliance must 
be specified in the instruction.

CAUTION:

A shielded-type power cord is

required in order to meet FCC emission limits
and also to prevent interference to the nearby
radio and television reception.  It is essential
that only the supplied power cord be used.
Use only shielded cables to connect I/O
devices to this equipment.

CAUTION:

Any changes or modifications not

expressly approved by the guarantee of this
device could void the user's authority to 
operate the equipment.

PANAMAX MAX® 1500-UPS LIMITED 

PRODUCT WARRANTY

Panamax warrants to the purchaser of this
Panamax audio/video component style unin-
terruptible power supply, for a period of three
(3) years from the date of purchase, that the
unit shall be free of defects  in design, materi-
al, or workmanship, and Panamax will repair
or replace any defective unit.

Upgrade Policy

Valid only in the United states and Canada

If your Panamax UPS sacrifices itself while
protecting your connected equipment, you
have an option to upgrade to the latest tech-
nology. Please go to our web site www.pana-
max.com/rma or contact Panamax Customer
Relations at 800-472-5555 for details.

Warning Notice
WARRANTY LIMITATION FOR INTERNET PUR-
CHASERS

Panamax products purchased through the
Internet do not carry a valid Connected
Equipment Protection Policy unless purchased
from an Authorized Panamax Internet Dealer!
Authorized Panamax Internet Dealers have suf-
ficient expertise to insure warranty compliant
installations. For a list of Authorized Panamax
Internet Dealers go to www.panamax.com

CAUTION

Audio/Video, computer and/or telephone sys-
tem installations can be very complex sys-
tems, which consist of many interconnected
components. Due to the nature of electricity
and surges, a single protector may not be able
to completely protect complex installations.       
In those cases, a systematic approach using

multiple protectors must be employed.
Systematic protection requires professional
design. AC power, satellite cables, CATV
cables, A/V signal line cables or telephone/net-
work lines entering the system that do not
pass through a Panamax surge protector will
render the Panamax connected equipment
protection policy null and void. For additional
information on how to protect your system,
please contact Panamax before connecting
your equipment to the surge protector.

More detailed information is available at
www.panamax.com

If you have any questions regarding these
requirements, please contact Panamax
Customer Relations.

Effective Date 11/04         Q01L0047 REV. A

1690 Corporate Circle, Petaluma, CA 94954

Tel: (707) 283-5900

Fax:: (707) 283-5901

Email: [email protected]

Web: www.panamax.com

© 2005 Panamax

17

FCC Notice and Warranties

Содержание M1500-UPS

Страница 1: ...ual POWER TEST MAX Home Cinema UPS Pure Sine Wave Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1690 Corporate Circle Petaluma CA...

Страница 2: ...tions pgs 7 8 9 10 Battery Features pgs 10 11 Diagnostics pg 11 Troubleshooting pg 12 Technical Specifications pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties...

Страница 3: ...ife support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the ris...

Страница 4: ...nd does not service equipment with large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be rated for 15 Amps 5 Press the power switch to t...

Страница 5: ...nd the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator...

Страница 6: ...th outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is output 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will...

Страница 7: ...me Cinema Power Control Software The M1500 UPS has one rear panel serial port that provides the ability to program special functions safely shutdown a home the ater PC HTPC or integrate the UPS with h...

Страница 8: ...and 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control...

Страница 9: ...own the HTPC during extended power fail ures This requires a permanent RS232 connection to the HTPC and having the Home Cinema Power Control software running in the background on the HTPC When a power...

Страница 10: ...ds to be used exclusively for the UPS software 12 Time between power failure and shutdown For use with an HTPC This is the user controllable delay between when the power fails and the software starts...

Страница 11: ...tes and times of any scheduled startups and shut downs 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is...

Страница 12: ...the red run button The unit will cycle to battery mode and emit an audible beep With the software self test the unit will switch back to AC power automatically Battery Replacement Read and follow the...

Страница 13: ...eps Rapid Beeps Long Beep Long Beep None Off None Condition Normal AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input v...

Страница 14: ..._____________________________Yes Maintenance free____________________________________________________________Yes Lead acid___________________________________________________________________Yes User re...

Страница 15: ...outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY M...

Страница 16: ...pace 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP...

Страница 17: ...is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to U...

Страница 18: ...n AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high...

Страница 19: ...e date of purchase that the unit shall be free of defects in design materi al or workmanship and Panamax will repair or replace any defective unit Upgrade Policy Valid only in the United states and Ca...

Страница 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 Email sales panamax com Web www panamax com 2005 Panamax INS0763 REV B 7 05...