background image

2. Event: 

When this option is

selected, the log will display a list
of events such as power failure,
program start, and program end.

3. Closed Application
Information: 

When this option

is selected, the log will display the
names and location of any files that
were auto-saved by the software.

1. Log Display:

This window displays
the information as
selected by the Event,
Closed Application
Information, or Data
Record option buttons.

6. Cancel: 

Closes

the window without
saving any changes.

7. Clear: 

Clears the

selected log.

5. OK: 

Closes the

window and saves
any changes. 

4. Data Record: 

When this

option is selected, the log will dis-
play a record of the items that are
shown in the main window.

10

USA & Canada (800) 472-5555  •  (707) 283-5900  •  Fax (707) 283-5901

Home Cinema Power Control Software Instructions 

(continued)

Battery Features

LOG MENU

Testing The Battery Backup Function

Once you have set up your UPS system, you may wish to test it.
Make sure that the UPS has been charged for at least 4 hours
before testing.

To test the UPS, simply depress the test button located on the
front of the unit. The unit will cycle to battery and emit an audible
beep. The unit will stop beeping when the test is complete.
You may also use the self-test function in the software.  To use
the software self-test, open the main window, and then click
mode on Setup. Click the red run button.  The unit will cycle to
battery mode and emit an audible beep.  With the software self-
test, the unit will switch back to AC power automatically. 

Battery Replacement

Read and follow the 

IMPORTANT SAFETY INSTRUCTIONS

before

servicing the battery.

Service the battery under the supervision of personnel knowl-
edgeable of batteries and their precautions.  

Servicing the bat-

tery can only be performed by qualified personnel.   

CAUTION! 

Use only the specified type of battery.  See your dealer

for replacement batteries.

CAUTION!

The battery may present the risk of electrical shock.  

Do not dispose of batteries in a fire as they may explode.  Follow
all local ordinances regarding proper disposal of batteries.

CAUTION! 

Do not open or mutilate the batteries.  Released elec-

trolyte is harmful to the skin and eyes and may be toxic

CAUTION!

A battery can present a high risk of short circuit cur-

rent and electrical shock.  Take the following precautions before
replacing the battery:

1.

Remove all watches, rings or other metal objects.

2.

Only use tools with insulated handles.

3.

Do not lay tools or metal parts on top of battery or any 

terminals.

4.

Wear rubber gloves and boots.

5.

Determine if the battery is inadvertently grounded.  If inadver-

tently grounded, remove source of ground. 

CONTACT WITH A

GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! 

The

likelihood of such shock will be reduced if such grounds are
removed during installation and maintenance (applicable to a 
UPS and a remote battery supply not having a grounded circuit).

Содержание M1500-UPS

Страница 1: ...ual POWER TEST MAX Home Cinema UPS Pure Sine Wave Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1690 Corporate Circle Petaluma CA...

Страница 2: ...tions pgs 7 8 9 10 Battery Features pgs 10 11 Diagnostics pg 11 Troubleshooting pg 12 Technical Specifications pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties...

Страница 3: ...ife support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the ris...

Страница 4: ...nd does not service equipment with large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be rated for 15 Amps 5 Press the power switch to t...

Страница 5: ...nd the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator...

Страница 6: ...th outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is output 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will...

Страница 7: ...me Cinema Power Control Software The M1500 UPS has one rear panel serial port that provides the ability to program special functions safely shutdown a home the ater PC HTPC or integrate the UPS with h...

Страница 8: ...and 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control...

Страница 9: ...own the HTPC during extended power fail ures This requires a permanent RS232 connection to the HTPC and having the Home Cinema Power Control software running in the background on the HTPC When a power...

Страница 10: ...ds to be used exclusively for the UPS software 12 Time between power failure and shutdown For use with an HTPC This is the user controllable delay between when the power fails and the software starts...

Страница 11: ...tes and times of any scheduled startups and shut downs 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is...

Страница 12: ...the red run button The unit will cycle to battery mode and emit an audible beep With the software self test the unit will switch back to AC power automatically Battery Replacement Read and follow the...

Страница 13: ...eps Rapid Beeps Long Beep Long Beep None Off None Condition Normal AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input v...

Страница 14: ..._____________________________Yes Maintenance free____________________________________________________________Yes Lead acid___________________________________________________________________Yes User re...

Страница 15: ...outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY M...

Страница 16: ...pace 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP...

Страница 17: ...is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to U...

Страница 18: ...n AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high...

Страница 19: ...e date of purchase that the unit shall be free of defects in design materi al or workmanship and Panamax will repair or replace any defective unit Upgrade Policy Valid only in the United states and Ca...

Страница 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 Email sales panamax com Web www panamax com 2005 Panamax INS0763 REV B 7 05...

Отзывы: